Grandstream Networks GVC3200 Administration Manual page 40

Video conference system for android
Hide thumbs Also See for GVC3200:
Table of Contents

Advertisement

It is used to configure the time period (in minutes) in which the device refreshes its
Register Expiration
registration with the specified registrar. The default setting is 60. The maximum
(m)
value is 64800 (about 45 days) and the minimum value is 1 minute.
It is used to configure the time period (in seconds) in which the device will retry the
Wait Time Retry
registration process in the event that is failed. The default setting is 20. The
Registration (s)
maximum value is 3600 (1 hour).
It is used to configure the local SIP port used to listen and transmit. The default
Local SIP Port
setting is 5060. The valid range is from 5 to 65535.
It is used to set if the device will subscribe voice message service. If it is set to "Yes",
SUBSCRIBE for
the device will periodically send SIP SUBSCRIBE message for Message Waiting
MWI
Indication service. GVC3200/GVC3202 supports both synchronized and non-
synchronized MWI. The default setting is "No".
It is used to set if the device will use the session timer. If it is set to "Yes", it will be
Enable Session
added in the SIP INVITE message to notify the server. The default setting is "Yes".
Timer
It is used to configure the device's SIP session timer. It enables SIP sessions to be
periodically "refreshed" via a SIP request (UPDATE, or re-INVITE). If there is no
Session Expiration
refresh via an UPDATE or re-INVITE message, the session will be terminated once
(s)
the session interval expires. Session Expiration is the time (in seconds) where the
session is considered timed out, provided no successful session refresh transaction
occurs beforehand. The default setting is 180. The valid range is from 90 to 64800.
It is used to configure the minimum session expiration timer (in seconds) if the
Min-SE (s)
device acts as a timer refresher. The default setting is 90. The valid range is from 90
to 64800.
It is used to set the party which will refresh the active session if the device makes
outbound calls. If it is set to "UAC" and the remote party does not support Refresher
UAC Specify
feature, the device will refresh the active session. If it is set to "UAS", the remote
Refresher
party will refresh it. If it is set to "Omit", the header will be omitted so that it can be
selected by the negotiation mechanism. The default setting is "Omit".
It is used to set the party which will refresh the active session if the device receives
inbound calls. If it is set to "UAC", the remote party will refresh the active session. If
UAS Specify
it is set to "UAS" and the remote party does not support refresh feature, the device
Refresher
will refresh it. The default setting is "UAC".
It is used to set the SIP message type to refresh the session. If it is set to "Yes", the
Session Timer will be refreshed by using the SIP INVITE message. Otherwise, the
Force INVITE
device will use the SIP UPDATE or SIP OPTION message. The default setting is
"No".
This is used to set the caller party to act as refresher. If set to "Yes" and both parties
Caller Request
support session timers, the device will enable the session timer feature when it
makes outbound calls. The SIP INVITE will include the content "refresher=uac". The
Timer
default setting is "No".
Firmware Version 1.0.1.48