PROCEDURE TO BE FOLLOWED
- Switch on the electric bilge pump.
- If necessary activate the manual pump.
- Identify the source of the leak by tasting the water and decide on the relevant action to
be taken:
• freshwater = watertank leak.
• seawater = breach of hull.
ELECTRIC BILGE PUMP
Location
Operation:
The electric bilge pumps are connected to the 12V service circuit. To enable operation
the 12V circuit must be activated by turning on the battery switches.
Capacity: 32 litre / minute
You can energize the electric bilge pump from the instrument panel.
MANUAL BILGE PUMP
Location: in the cockpit.
The control arm of the pump shall be kept accessible whatever the circumstances.

BILGE PUMP SYSTEM