Siemens SCALANCE X320-3LD FE Operating Instructions Manual page 212

Industrial ethernet switches
Hide thumbs Also See for SCALANCE X320-3LD FE:
Table of Contents

Advertisement

Technical specifications
8.9 MM900 technical specifications
Fiber-optic cables
Table 8- 129 Permitted cable lengths (fiber-optic cable - Fast Ethernet)
Media module
Fiber-optic cable type
MM991-2
50/125 µm
multimode fiber
62.5/125 µm multi-
mode fiber
MM991-2FM
50/125 µm
multimode fiber
62.5/125 µm multi-
mode fiber
MM991-2LD
9/125 µm
single mode fiber
MM991-2 (SC)
50/125 µm
multimode fiber
62.5/125 µm multi-
mode fiber
MM991-2LD
9/125 µm
(SC)
single mode fiber
MM991-2LH+
9/125 µm
(SC)
single mode fiber
MM991-2P
980/1000
plastic optical fiber
200/230
polymer cladded fiber
Table 8- 130 Permitted cable lengths (fiber-optic cable - gigabit Ethernet)
Media module
Fiber-optic cable
type
MM992-2
62.5/125 µm
multimode fiber
MM992-2 (C)
50/125 µm
multimode fiber
212
Max. permitted
Attenuation
cable length
5 km
≤1 dB/km at 1310 nm; 1200 MHz×km; maximum insertion
loss 0.5 dB; 9 dB max. permitted FO cable attenuation at
3 dB link power margin
5 km
≤1 dB/km at 1310 nm; 1200 MHz×km; maximum insertion
loss 0.5 dB; 9 dB max. permitted FO cable attenuation at
3 dB link power margin
5 km
≤1 dB/km at 1310 nm; 1200 MHz×km; maximum insertion
loss 0.5 dB; 9 dB max. permitted FO cable attenuation at
3 dB link power margin
5 km
≤1 dB/km at 1310 nm; 1200 MHz×km; maximum insertion
loss 0.5 dB; 9 dB max. permitted FO cable attenuation at
3 dB link power margin
26 km
≤0.5 dB/km at 1310 nm; maximum insertion loss 0.5 dB; 14
dB max. permitted FO cable attenuation at 2 dB link power
margin
5 km
≤1 dB/km at 1310 nm; 1200 MHz×km; maximum insertion
loss 0.5 dB; 9 dB max. permitted FO cable attenuation at
3 dB link power margin
5 km
≤1 dB/km at 1310 nm; 1200 MHz×km; maximum insertion
loss 0.5 dB; 9 dB max. permitted FO cable attenuation at
3 dB link power margin
26 km
≤0.5 dB/km at 1310 nm; maximum insertion loss 0.5 dB; 14
dB max. permitted FO cable attenuation at 2 dB link power
margin
70 km
≤0.28 dB/km at 1550 nm; maximum insertion loss 0.5 dB;
26 dB max. permitted FO cable attenuation at 2 dB link power
margin, minimum cable attenuation 3 dB
50 m
9 dB max. permitted FO cable attenuation with 3 dB link
power margin
100 m
6 dB max. permitted FO cable attenuation with 3 dB link pow-
er margin
Max. permitted
Attenuation
cable length
350 m
≤3.1 dB/km at 850 nm; 1200 MHz×km; maximum insertion
loss 0.5 dB; 4.5 dB max. permitted FO cable attenuation at
3 dB link power margin
750 m
≤2.5 dB/km at 850 nm; 1200 MHz×km; maximum insertion
loss 0.5 dB; 4.5 dB max. permitted FO cable attenuation at
3 dB link power margin
Operating Instructions, 05/2016, A5E01113043-20
SCALANCE X-300

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents