Connectors And Electrical Data - Siemens SCALANCE X320-3LD FE Operating Instructions Manual

Industrial ethernet switches
Hide thumbs Also See for SCALANCE X320-3LD FE:
Table of Contents

Advertisement

Technical specifications
8.8 XR-300M PoE technical specifications
8.8.2

Connectors and electrical data

Table 8- 104 Connection for end devices or network components
Max. number
Electrical
Media module slots
Transmitter output (optical) and receiver input
Diagnostics port
Table 8- 105 Electrical data: Power supply
Device version
(power supply)
24 VDC
100 to 240 VAC
Table 8- 106 Electrical data: Current consumption and power loss
Device version
(power supply)
24 VDC
100 to 240 VAC
incl. PoE power supply of the connected PoE devices (PDs)
1)
200
Redundant
Redundant power
power supply unit
supply possible
No
No
Current consumption
4.2 A
1,3 ... 0.7 A
24 ports
Port 1 to 8
8 x RJ-45 jacks, MDI-X pinning,
10/100/1000 Mbps (half/full duplex)
power supply for connected devices (PDs) using
Power over Ethernet (PoE) according to
IEEE 802.3af / 802.3at (type 1)
Port 9 to 16:
8 x RJ-45 jacks with MDI-X assignment
10/100/1000 Mbps (half / full duplex)
4 x modular
(2 ports per slot)
The values correspond to those of the permitted
MM900 media modules and SFP transceivers.
RJ-11 jack
Yes
Rated voltage
Voltage range
Permitted voltage
range incl. total
ripple
No
Effective power loss
46 W
42 W
Operating Instructions, 05/2016, A5E01113043-20
Power supply
24 VDC
19.2 VDC - 28.8
VDC
18.5 VDC - 30.2
VDC
100 to 240 VAC
(85 to 264 V)
Max. power consumption
100 W
96 W
SCALANCE X-300