Technical specifications
8.2 X-300 technical specifications
Table 8- 12
Permitted cable lengths (fiber-optic cable - Fast Ethernet)
Device variant
Fiber-optic cable
type
X304-2FE,
50/125 µm
X320-1 FE
multimode fiber
62.5/125 µm multi-
mode fiber
X306-1LD FE
9/125 µm
single mode fiber
X310FE
-
X320-3LD FE
50/125 µm
multimode fiber
9/125 µm
single mode fiber
Table 8- 13
Permitted cable lengths (fiber-optic cable - gigabit)
Device variant
Fiber-optic cable
type
X307-3,
62.5/125 µm
X308-2
multimode fiber
50/125 µm
multimode fiber
X307-3LD
9/125 µm
X308-2LD
single mode fiber
X308-2LH
9/125 µm
single mode fiber
X308-2LH+
9/125 µm
single mode fiber
X310
-
162
Permitted cable length
0 to 5 km
0 ... 5 km
0 to 26 km
-
0 to 5 km
0 to 26 km
Permitted cable length
0 to 350 m
0 to 750 m
0 to 10 km
... 40 km
... 70 km
-
Attenuation
≤1 dB/km at 1310 nm; 1200 MHz×km; maximum
insertion loss 0.5 dB; 9 dB max. permitted FO cable
attenuation at 3 dB link power margin
≤1 dB/km at 1310 nm; 1200 MHz×km; maximum
insertion loss 0.5 dB; 9 dB max. permitted FO cable
attenuation at 3 dB link power margin
≤0.5 dB/km at 1310 nm; maximum insertion loss 0.5
dB; 14 dB max. permitted FO cable attenuation at 2
dB link power margin
-
≤1 dB/km at 1310 nm; 1200 MHz×km; maximum
insertion loss 0.5 dB; 9 dB max. permitted FO cable
attenuation at 3 dB link power margin
≤0.5 dB/km at 1310 nm; maximum insertion loss 0.5
dB; 14 dB max. permitted FO cable attenuation at 2
dB link power margin
Attenuation
≤3.1 dB/km at 850 nm; 1200 MHz×km; maximum
insertion loss 0.5 dB; 4.5 dB max. permitted FO
cable attenuation at 3 dB link power margin
≤2.5 dB/km at 850 nm; 1200 MHz×km; maximum
insertion loss 0.5 dB; 4.5 dB max. permitted FO
cable attenuation at 3 dB link power margin
≤0.5 dB/km at 1310 nm; maximum insertion loss 0.5
dB; 6 dB max. permitted FO cable attenuation at 3
dB link power margin
≤0.4 dB/km at 1550 nm; maximum insertion loss
0.5 dB; 18 dB max. permitted FO cable attenuation
at 2 dB link power margin; minimum cable attenua-
tion 3 dB
≤0.28 dB/km at 1550 nm; maximum insertion loss
0.5 dB; 21 dB max. permitted FO cable attenuation
at 2 dB link power margin; minimum cable attenua-
tion 8 dB
-