Connectors And Electrical Data - Siemens SCALANCE X320-3LD FE Operating Instructions Manual

Industrial ethernet switches
Hide thumbs Also See for SCALANCE X320-3LD FE:
Table of Contents

Advertisement

8.5.2

Connectors and electrical data

Table 8- 52
Device variant
X302-7EEC
(all variants)
X307-2EEC
(all variants)
Table 8- 53
Device version
(power supply)
1 power supply unit
24 to 48 VDC
2 power supply units
24 to 48 VDC
1 x power supply unit 100
to 240 VAC / 60 to 250
VDC
2 x power supply units
100 to 240 VAC / 60 to
250 VDC
With a redundant 24 VDC power supply, "L1" must be connected on both power supply units.
1)
AC 50/60 Hz ±5 %
2)
Table 8- 54
Electrical data: Current consumption and power loss
Device variant
X302-7ECC
X307-2ECC
SCALANCE X-300
Operating Instructions, 05/2016, A5E01113043-20
Connection for end devices or network components
Electrical
over twisted pair
2 x RJ-45 jacks with MDI-X assignment
10/100/1000 Mbps (half / full duplex)
7 x RJ-45 jacks with MDI-X assignment
5 x Fast Ethernet 10/100 Mbps
(half/full duplex)
2 x Gigabit Ethernet
10/100/1000 Mbps (half/full duplex)
Electrical data: Power supply
Redundant
power supply
unit
No
Yes
No
Yes
Device version
(power supply)
24 to 48 VDC
100 to 240 VAC / 60 to 250
VDC
24 to 48 VDC
100 to 240 VAC / 60 to 250
VDC
8.5 Technical specifications for X-300EEC
Optical
over fiber-optic cable
7 x LC sockets multimode
(100 Mbps, full duplex)
2 x LC sockets multimode
(100 Mbps, full duplex)
Redundant power sup-
ply possible
Yes
Yes
1)
No
Yes
Current consumption
0.8 to 0.4 A
0.4 to 0.3 A (AC)
0.3 to 0.1 A (DC)
0.5 to 0.3 A
0.3 to 0.2 A (AC)
0.3 to 0.1 A (DC)
Technical specifications
Power supply
(min./max. range)
24 to 48 VDC
(19.2 to 57.6 VDC)
24 to 48 VDC
(19.2 to 57.6 VDC)
100 to 240 VAC
(80 to 276 VAC)
2)
60 to 250 VDC
(46.25 to 300 VDC)
100 to 240 VAC
(80 to 276 VAC)
2)
60 to 250 VDC
(46.25 to 300 VDC)
Effective power loss
17 W
18 to 19 W (AC)
17 to 18 W (DC)
12 W
12 to 13 W (AC)
12 to 13 W (DC)