Cable Lengths - Siemens SCALANCE X320-3LD FE Operating Instructions Manual

Industrial ethernet switches
Hide thumbs Also See for SCALANCE X320-3LD FE:
Table of Contents

Advertisement

Table 8- 39
Device version
(power supply)
2 x 24 VDC
1 x 100 to 240 VAC
Table 8- 40
Device version
(power supply)
2 x 24 VDC
1 x 100 to 240 VAC
Table 8- 41
Voltage via signaling contact
Switching capacity (resistive load)
Table 8- 42
Device version
(power supply)
2 x 24 VDC
1 x 100 to 240 VAC
8.4.3

Cable lengths

Table 8- 43
Cable type
IE TP torsion cable
IE FC TP Marine Cable
IE FC TP Trailing Cable
IE FC TP Flexible Cable
IE FC TP standard cable
SCALANCE X-300
Operating Instructions, 05/2016, A5E01113043-20
Electrical data: Current consumption and power loss
Electrical data: Overcurrent protection
Electrical data: Signaling contact
Plug-in terminal block for connectors of the power supply and signaling contact
Power supply
2 x 4-pin
1 x 2-pin
Permitted cable lengths (copper cable - Fast Ethernet)
Accessory (plug, outlet,
TP cord)
with IE FC Outlet RJ-45
+ 10 m TP cord
with IE FC RJ-45 Plug 180
with IE FC Outlet RJ-45
+ 10 m TP cord
with IE FC RJ-45 Plug 180
with IE FC Outlet RJ-45
+ 10 m TP cord
with IE FC RJ-45 Plug 180
8.4 XR-300M technical specifications
Current consumption
1.8 A
0.8 to 0.45 A
Overcurrent protection of the power supply
Non-replaceable fuse
5 A / 125 V
3.15 A / 250 V
24 VDC
max. 100 mA
Technical specifications
Effective power loss
44 W
50 W
Signaling contact
2 x 2-pin
1 x 2-pin
Permitted cable length
0 to 45 m
+ 10 m TP cord
0 to 55 m
0 to 75 m
+ 10 m TP cord
0 to 85 m
0 to 90 m
+ 10 m TP cord
0 to 100 m
173

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents