700-3 SERIES - TALL UNITS
CODE INDICATION
05
Ref. cabinet therm. read open, short or erratic temp for 10+ sec's
06
Ref. evap. therm. read open, short or erratic temp for 10+ sec's
07
Fre. cabinet therm. read open, short or erratic temp for 10+ sec's
08
Fre. evap. therm. read open, short or erratic temp for 10+ sec's
20
Defrost underheat & no feedback thru Gr/Wh wire at defrst start
21
Defrost overheat
22
No feedback thru Gr/Wh wire at defrost start
23
Defrost overheat & no feedback thru Gr/Wh wire at defrost start
24
Defrost underheat
30
Excess IM Water Valve Solenoid Activation (> 15 Seconds)
40
Excessive Freezer Comp Run
50
Excessive Refrigerator Comp Run
NOTE: To clear Error Codes, see next page.