700-2 SERIES (Tall Units)
NOTE: The table on the preceding page will be updated through
addendums when subsequent software and electrical changes occur
and more error codes are added. Error Codes 80 - 88 apply to the
700TF/I-2V only, which started at serial ##1898164.
»
Clearing Error Codes
1.
Unit must be ON
2.
Repair problem
3.
Press and hold Bell ON/OFF key for 15 seconds
»
Manual Component Activation Mode
(Energizes cooling system for 5 minutes)
1.
Unit must be ON
2.
Press desired COLDER & UNIT ON/OFF keys simultane-
ously for 10 seconds
NOTE: After performing the above key strokes (depending on
COLDER key chosen), the following will appear on the LCD.
Temperatures shown are for reference only, actual temperatures
may vary.
- - 1 1 8 8
Temperature of FE (Freezer Evaporator)
OR
2 2 9 9
Temperature of rE (Refrigerator Evaporator)
SERVICE (Illuminated)
SERVICE (Illuminated)
PAGE 72
Starting W/ Serial #1759163
F F E E
rE E