Sub-Zero 400 Series Information Booklet page 71

Condensed electronic control
Hide thumbs Also See for 400 Series:
Table of Contents

Advertisement

700-2 SERIES (Tall Units)
CODE INDICATION
05
Ref. cabinet therm. read open, short or erratic temp for 10+ sec's
06
Ref. evap. therm. read open, short or erratic temp for 10+ sec's
07
Fre. cabinet therm. read open, short or erratic temp for 10+ sec's
08
Fre. evap. therm. read open, short or erratic temp for 10+ sec's
20
Defrost underheat & no feedback thru Gr/Wh wire at defrst start
21
Defrost overheat
22
No feedback thru Gr/Wh wire at defrost start
23
Defrost overheat & no feedback thru Gr/Wh wire at defrost start
24
Defrost underheat
80
High VS compressor differential pressures or low voltage sup-
plied to VS compressor
81
High Amperage Draw at VS compressor
82
VS comp. couldn't maintain min. speed at highest current draw
83
Locked VS compressor Rotor
84
Short circuit at VS compressor controller output circuit
85
VS compressor inverter overheated & shut down VS compressor
86
Serial communication failure between VS compressor controller
and electronic control board
87
Speed information from electronic control board is out of spec.
88
Electronic control board not receiving status data in response to
speed commands
NOTE: VS Compressor = Variable Speed Compressor
Error Code Table
PAGE 71