700-3 SERIES - TALL UNITS
Possible Error Indicators
NOTE: Temperatures shown are for reference only, actual tempera-
tures may vary.
E E E E
Freezer compartment thermistor fault
0 0 0 0
Refrigerator compartment thermistor fault
0 0 0 0
Several excessive compressor run periods OR
Refrigerator evaporator thermistor fault
0 0 0 0
Water valve energized longer than 15 seconds, five consec-
utive times. Icemaker system disabled 24 hours each time.
NOTE: A 45 minute dwell follows each IM cycles (no power
to Icemaker). To bypass 45 minute dwell, Switch ice maker
system OFF then back ON.
0 0 0 0
Error Codes logged and observed but not cleared.
NOTE: To clear Error Codes, press bell ON/OFF key for 15 sec-
onds.
SERVICE (Flashing)
SERVICE (Flashing)
SERVICE (Flashing)
SERVICE (Flashing)
ICE (Flashing)
SERVICE (Steady, not Flashing)3 3 8 8
PAGE 79
3 3 8 8
E E E E
3 3 8 8
3 3 8 8