648PRO & ICB648PRO Error Code Table
EC ZONE SERVICE INSTRUCTION
01
X
Zone "X" Cabinet Thermistor Failure (Device or Wiring)
02
X
Zone "X" Evaporator Thermistor Failure (Device or Wiring)
03
X
Zone "X" Condenser Thermistor Failure (Device or Wiring)
04
0
Ambient Thermistor Failure (Device or Wiring)
20
X
Check Zone "X" Defrost Bi-metal for Proper Operation
21
X
Check Zone "X" Defrost Bi-metal for Proper Operation
22
X
Check Zone "X" Defrost Wiring
23
X
Check Zone "X" Defrost Wiring
24
X
Check Zone "X" Defrost Heater Ohms
30
0
Check for Stuck Icemaker or Water Valve Failure
35
X
Check Zone "X" Fan, Fan Speed Error
40
X
Zone "X" Excessive Run
41
X
Check Zone "X" Compressor and Wiring
42
0
Check Condenser Fan and/or Wiring
43
X
Check Left Refrigerant Valve and Wiring
44
X
Check Zone "X" Glass Door Heater and Wiring
45
X
Errors Detectable with Red Door Switches-Disabled Now.
Check Overhead Lighting
46
0
Check Ice Accessory Wiring for Open Circuit
47
3
Check Accent Lighting Wiring for Short Circuit
80
X
Check Power to Compressor Controller for Zone "X",
Troubleshoot with Manual Activation Mode
83
X
Replace Zone "X" VS Compressor and Filter-Drier
84
X
Check Zone "X" VS Compressor Wiring
85
X
Zone "X" VS Compressor Control Overheat
86
X
Check Communication Wiring, Replace Zone "X" VS
Controller
87
X
Check for Broken Wiring or Open Defrost Heater
89
X
Check Icemaker Solenoid Valve and Wiring
90
X
Change Main Control Board
PAGE 110