400-2 SERIES WINE STORAGE
»
Temperature Log Recall Mode
(Compartment Temperature History Only)
1.
Unit must be ON
2.
Press desired WARMER & UNIT ON/OFF keys simultane-
ously, then release both keys
NOTE: After performing the above key strokes (depending on
COLDER key chosen), the following will appear on the display.
Temperatures shown are for reference only, actual temperatures
may vary.
5 5 3 3
4 hour compartment temperature average (at left) with
index number. Number 1 is most recent 4 hour period.
NOTE: SERVICE is always illuminated at first index.
-
Press WARMER key in multiple keystrokes to toggle up
through indexes, from 1 to 64.
6 6 0 0
4 hour compartment temperature average (at left) with
index number. Number 64 is oldest recorded 4 hour period.
-
Press COLDER key in multiple keystrokes to toggle down
through indexes, from 64 to 1.
NOTE: See following page for possible event indicators during
Temperature Log Recall Mode. Temperature Log Recall Mode
will end 10-15 seconds after last key stroke.