York HMH7 Series Technical Manual

York HMH7 Series Technical Manual

Horizontal discharge modulating heat pump

Advertisement

YORK Technical Guide: HMH7 Series - 17
SEER Horizontal Discharge Modulating
Heat Pump
R-410A 2 to 5 Nominal Ton
York International Corporation, 5005 York
6062825-YTG-A-0321
Drive, Norman, OK 73069
Supersedes: Nothing
A
2021-03-25
Johnson Controls Ducted Systems

Advertisement

Table of Contents
loading

Summary of Contents for York HMH7 Series

  • Page 1 YORK Technical Guide: HMH7 Series - 17 SEER Horizontal Discharge Modulating Heat Pump R-410A 2 to 5 Nominal Ton York International Corporation, 5005 York 6062825-YTG-A-0321 Drive, Norman, OK 73069 Supersedes: Nothing 2021-03-25 Johnson Controls Ducted Systems...
  • Page 2 YORK Technical Guide: HMH7 Series - 17 SEER Horizontal Discharge Modulating Heat Pump Johnson Controls Ducted Systems...
  • Page 3: Table Of Contents

    Heating performance data - 4 ton....................19 Performance data - 5 ton..........................20 Cooling performance data - 5 ton....................20 Heating performance data - 5 ton....................20 YORK Technical Guide: HMH7 Series - 17 SEER Horizontal Discharge Modulating Heat Pump Johnson Controls Ducted Systems...
  • Page 4 YORK Technical Guide: HMH7 Series - 17 SEER Horizontal Discharge Modulating Heat Pump Johnson Controls Ducted Systems...
  • Page 5: Description

    Visit us on the web at www.simplygettingthejobdone.com www.york.com Additional rating information can be found at www.ahridirectory.org. Certification The units are tested in accordance with the following: YORK Technical Guide: HMH7 Series - 17 SEER Horizontal Discharge Modulating Heat Pump Johnson Controls Ducted Systems...
  • Page 6: Warranty Summary

    • Agency Listed: Safety certified by CSA to UL 1995/CSA 22.2. Performance certified to ANSI/ AHRI Standard 210/240 in accordance with the Unitary Small Equipment certification program. YORK Technical Guide: HMH7 Series - 17 SEER Horizontal Discharge Modulating Heat Pump Johnson Controls Ducted Systems...
  • Page 7: Nomeclature

    C =Communicating B = Wireless (communicating) S = Standard (conventional) W = Wireless (conventional) Style A = Style A B = Style B YORK Technical Guide: HMH7 Series - 17 SEER Horizontal Discharge Modulating Heat Pump Johnson Controls Ducted Systems...
  • Page 8: Physical And Electrical Data

    • For applications with non-standard vapor line sizes, see Applications and accessories. YORK Technical Guide: HMH7 Series - 17 SEER Horizontal Discharge Modulating Heat Pump Johnson Controls Ducted Systems...
  • Page 9: Dimensions

    HMH72B361S HMH72B481S HMH72B601S Required TXV Indoor unit additional charge (oz) AE18B AE24B AE30B AE36(C,B) AE42C AE43C AE48(C,D) AE60(C) AE60(D) AVC18B AVC24B AVC30B AVC36(B,C) YORK Technical Guide: HMH7 Series - 17 SEER Horizontal Discharge Modulating Heat Pump Johnson Controls Ducted Systems...
  • Page 10: Charging Procedure

    For downflow installations and horizontal right installations, some indoor units require additional charging adjustments to ensure correct equipment operation. Refer to the Installation Manual for the outdoor unit. YORK Technical Guide: HMH7 Series - 17 SEER Horizontal Discharge Modulating Heat Pump Johnson Controls Ducted Systems...
  • Page 11: System Capacity

    122 (50) 75 (24) Note: The maximum lineset equivalent length is 200 ft. The following accessories are compatible with H Series heat pumps: YORK Technical Guide: HMH7 Series - 17 SEER Horizontal Discharge Modulating Heat Pump Johnson Controls Ducted Systems...
  • Page 12: Sound Power Ratings

    • Unit cabinet components shall be G90 equivalent steel finished with powder-coat paint rated at a minimum of 1,000 h under ASTM B117 testing. YORK Technical Guide: HMH7 Series - 17 SEER Horizontal Discharge Modulating Heat Pump Johnson Controls Ducted Systems...
  • Page 13: Typical Installation

    Care must be taken to prevent ice from damaging the unit. Damage may occur from ice falling onto unit from a sloped roof or from a vertical drip line due to a partial overhang. YORK Technical Guide: HMH7 Series - 17 SEER Horizontal Discharge Modulating Heat Pump Johnson Controls Ducted Systems...
  • Page 14: Typical Field Wiring

    Typical field wiring Figure 4:  Typical field wiring - HMH72B241S and HMH72B361S YORK Technical Guide: HMH7 Series - 17 SEER Horizontal Discharge Modulating Heat Pump Johnson Controls Ducted Systems...
  • Page 15: Alternative Installation Clearances

    Figure 5:  Typical field wiring - HMH72B481S and HMH72B601S Alternative installation clearances Figure 6:  Alternative installation clearances YORK Technical Guide: HMH7 Series - 17 SEER Horizontal Discharge Modulating Heat Pump Johnson Controls Ducted Systems...
  • Page 16: Performance Data - 2 Ton

    2.46 2.16 18.3 2.68 2.00 16.4 2.10 2.29 17.2 2.21 2.28 17.9 2.31 2.27 17.2 1.86 2.71 18.7 2.05 2.68 20.3 2.24 2.65 YORK Technical Guide: HMH7 Series - 17 SEER Horizontal Discharge Modulating Heat Pump Johnson Controls Ducted Systems...
  • Page 17: Performance Data - 3 Ton

    • All capacities include indoor fan heat. kW values are for the system (outdoor + indoor). • Drive output is limited in the shaded area. Performance may vary and interpolation is not permissable. YORK Technical Guide: HMH7 Series - 17 SEER Horizontal Discharge Modulating Heat Pump Johnson Controls Ducted Systems...
  • Page 18: Heating Performance Data - 3 Ton

    34.6 34.0 26.8 31.4 34.2 38.1 37.2 28.7 4.48 4.53 4.53 4.58 4.79 4.64 4.67 4.68 4.73 4.93 4.79 4.81 4.83 4.89 5.07 YORK Technical Guide: HMH7 Series - 17 SEER Horizontal Discharge Modulating Heat Pump Johnson Controls Ducted Systems...
  • Page 19: Heating Performance Data - 4 Ton

    16.7 1.39 3.54 16.9 1.37 3.60 Note: • All capacities include indoor fan heat. kW values are for the system (outdoor + indoor). YORK Technical Guide: HMH7 Series - 17 SEER Horizontal Discharge Modulating Heat Pump Johnson Controls Ducted Systems...
  • Page 20: Performance Data - 5 Ton

    3.09 4.39 47.5 3.18 4.38 42.4 2.67 4.66 43.3 2.72 4.65 46.4 2.92 4.65 39.7 2.35 4.94 42.5 2.50 4.98 45.2 2.64 5.02 YORK Technical Guide: HMH7 Series - 17 SEER Horizontal Discharge Modulating Heat Pump Johnson Controls Ducted Systems...
  • Page 21 23.6 1.60 4.31 26.3 1.75 4.42 Note: • All capacities include indoor fan heat. kW values are for the system (outdoor + indoor). YORK Technical Guide: HMH7 Series - 17 SEER Horizontal Discharge Modulating Heat Pump Johnson Controls Ducted Systems...
  • Page 22 Subject to change without notice. Published in U.S.A. Copyright © 2021 by Johnson Controls. All rights reserved. Johnson Controls Ducted Systems...

This manual is also suitable for:

Hmh72b241sHmh72b361sHmh72b481sHmh72b601s

Table of Contents