SECTION 4
DESCRIPTION Of OPERATION
4.10.9 Power Board_PCB2 CNC Interface (0558038315)
The PC1600 is designed to be used in a mechanized environment. The CNC interface connector J8 is used
to connect to the Remote board PCB6, which will interface with a CNC via the J2 Amphenol plug.
The J8 connector passes all signals but one, the external reference signal, to the main control board PCB1
through the PCB2 J4 - PCB1 J1 ribbon cable. The external reference signal, used to set the output current
of the PC1600 remotely, is connected to the main control board through the PCB2 J7 – PCB1 J2 ribbon
cable.
4.10
70