SECTION 4
4.18
Remote_PCb6 (0558038337)
1
2 - 3
4
5
6
7 - 8
9 - 10
1
2 - 4
5
6
7
8
0558038337 PCB6 Remote PC Board
Ground
Current reference from the CNC
+15 VDC
Start Signal
Corner
ARC ON
FAULT
0558038337 PCB6 Remote PC Board
Ground
Current reference from the CNC
Start Signal
Corner
FAULT
ARC ON
DESCRIPTION Of OPERATION
J1
0 - 10 VDC
+15 VDC active
+15 VDC active
Relay contacts for output to CNC
Relay contacts for output to CNC
P1
0 - 5 VDC
+15 VDC active
+15 VDC active
active low to close the relay RL1
active low to close the relay RL2