SECTION 7
4. Cut the tie wraps, unplug control transformer wires to allow for easier cable
routing (on a multi-voltage unit unplug voltage select switch wires also).
5. Thread the cable through the hole as shown and allow
cable to hang loose. Add locknut and partially tighten.
6. Assemble the cable clamp onto the
exposed shield area and attach to
the frame with the screw provided.
Orient clamp downward as shown.
cable clamp
154
MEChANIZED CONVERSION
Cut the tie wraps here
cable clamp in postion