1. TECHniCal sPECiFiCaTiOns
Supply voltage
Power consumption, average
Main power switch
Relay output - heating cable
Ambient temperature – operation
Ambient temperature – transport
Temperature range, floor sensor +5 +35°C
Temperature range, room
sensor
Accuracy – floor/room sensor
Switching hysteresis
Control modes
Economy programs
EcoHome; EcoOffice
Back-up for set values
Back-up for time and date
Optional external control
Protection class
Terminals
Floor sensor with 3 m cable
Maximum length of floor sensor
cable
Dimension with frame (Fig.1)
Colour
Approvals
8
230VAC, +10%,
–15%, 50/60 Hz
4 VA
2-pole
230V, max. 13A
0 +40°C
–20 +50°C
+5 +40°C
± 0,5°C
0,5°C (Factory settings
adjustable between
0,2-2.0°C)
Floor sensor
Room sensor
Room sensor with floor
sensor as a limiter
(Not in Comfort mode
2 preset-programs;
editable in time blocks of
30 min
In non-volatile memory
24 hours
Set back function
–3.5°C (Not in programs
EcoHome and EcoOffice)
IP 21
Max. 2,5 mm
NTC, 10K / 25°C.
100 m, 2 x 1,5 mm
(230VAC cable type)
H 82 x W 82 x D 57 mm
Polar white RAL 9010
Semko, VDE, eu.bac, CE
)
2