• Floor sensor: the user can adjust the difference
between the temperature inside the floor and the
room temperature.
Offset = Floor temperature – room temperature
Example: Use the floor sensor temperature value
from menu 1. If this value is 27°C and the floor
surface thermometer shows 24°C, the new offset
value will be 27-24 = 3.
Change the offset from 4°C to 3°C.
Push confirmation button several times (scroll
through Menu structure) to return to Normal mode

5.3.3 Menu 3: Delayed start-up

The user can choose the time before powering up
the floor warming system.
Possible values: from 0 [OFF] to 15 minutes [15 '].
A "t" is shown on in the display when the delayed
start-up is switched on.
22
New offset = T
- T
menu 1
surface
T surface
T menu1