This function will run at every factory reset of the
thermostat, if no floor sensor is attached.

5.2. Optional functions

5.2.1 activating Heat booster < >
This function is used for temporary increase of the
floor/room temperature by 5°C.
Push the confirmation button <
current set temperature will increase by 5°C for 2
hours and this increased temperature is shown on
the display. This automatically reverts to the set
temperature after 2 hours or if the confirmation
button is pushed again for 3 sec. within the 2 hour
period.
if external control is connected: Push the
confirmation button <
thermostat will now be in Manual mode. Push again
the confirmation button <
for 3 sec. The thermostat will go in "booster" mode
and the current set temperature will increase by 5°C
for 2 hours. This increased temperature is shown on
the display. Automatic reverts to the set temperature
after 2 hours or if the confirmation button <
pushed again for 3 sec. within the 2 hour period.
5.2.2 External set back
To utilise the set-back function and reduce the
current set point by 3.5°C: Connect a closing contact
between the FP terminal and phase terminal e.g.
a closing timer switch. When the contact is closed,
the symbol "P" is displayed in the lower right corner,
indicating activation.
To enable manual control mode: Push the
confirmation button for 3 seconds. Normal set
temperature control is active. Push again the
confirmation button <
3 seconds to change the Manual mode to Booster
mode. Push the confirmation button <
seconds to revert to AUTO mode.