8. teCHnICAL sPeCIFICAtIon

Supply voltage
Power consumption (Stand-by)
Relay output
Ambient temperature – operation
Ambient temperature – transport
Temperature range, floor sensor
Temperature range, room sensor
Switching hysteresis
Control modes
Temperature control
Protection class
Terminals
Floor sensor with 3 m cable
Maximum length of floor sensor
Cable
Approvals
22
230VAC, +10%, –15%, 50Hz
3 VA
230V, maximum 13A resistive
load (max. 3000W)
0 .. 40°C, 5-95% RH (non
condensing)
–10 .. +60°C
+5 .. +35°C
+5 .. +40°C
1°C (Factory settings adjustable
between 0.5-2.0°C)
Floor sensing
Room sensing
Room sensing with floor
temperature limiter
Manual ON/OFF
Timer programme
IP 20
Max. 2,5 mm²
NTC, 10KΩ / 25°C
100 m, 2 x 1,5 mm² (230VAC
cable type)
CE