Installer's Menu; Menu 1: Sensor Mode - Pentair NRG-Temp Operation Manual

Hide thumbs Also See for NRG-Temp:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Pressing <
from temperature view to time view.
Exceptions :
• During "First warming" function, the temperature
view is replaced by "First warming" elapse time
counter view.
• During learning function, the temperature view is
replaced by setting temperature value. Pressing
<
period for a duration of 3 seconds.
6.3. installers's menu
Changing various standard settings of the
thermostat.
To enter following menus push and hold the
<
> button for 6 sec. Use the <
to step through the menu's.

Menu 1: sensor mode

Menu 1: sensor regulation choice
If an external sensor is attached, the user is allowed
to choose between 2 regulation modes :
1. Floor sensor only
To change the operating mode to room sensing with
floor sensor as limiter, press the <
until <
If the floor sensor is not detected, it operates in room
sensing mode <
30
> key for 1s switches the view mode
> allows the user to view the elapsed learning
The sensor mode is detected and
initialised automatically. If the floor
sensor cable is connected, it operates
in floor sensor mode <
If no external sensor is attached the
thermostat works with room sensor
only and the user may not change it.
> is displayed. Confirm by pressing <
>.
> button
>.
2. Room with
floor limitation
> buttons
>.