New offset = T menu 2 - T surface
Example: Use the floor sensor temperature value
from menu 2. If this value is 27°C and the floor
surface thermometer shows 24°C, the new offset
value will be 27-24 = 3.
Change the offset from 4°C to 3°C.
Menu 4:
Display back-light "on" duration
Setting of the display backlight.
Change the time with <
Confirm with <
Menu 5:
Minimum temperature set point for the room sensor
Change the temperature value with <
Confirm by pressing <
> button.
Possible values: from 0 [OFF]
to 120 seconds [120'']
Factory value: 30s
> button.
Possible values: from 5°C [5.0]
to 15°C [15.0] (room regulation)
Factory set value: 5.0°C
T
menu2
> buttons.
> buttons
T
surface