safe) and an errorcode is displayed.
The floor sensor has the following temperature /
resistance values:
15°C / 15,8 kΩ
20°C / 12,5 kΩ
25°C / 10,0 kΩ
30°C / 8,04 kΩ
35°C / 6,51 kΩ
The floor sensor may be replaced by a new one. In
the event of malfunction of the room sensor the
entire thermostat must be replaced.
9. rEsET TO FaCTOry sETTinGs.
See page 36.
To reset: Push the small button on the right side
of the power (on/off) switch, on the front of the
thermostat. All set values will return to factory
defaults. The thermostat will re-boot.