5.3.4 Menu 4:
from 0 [OFF] to 120 seconds [120''] Factory value: 30s

5.3.5 Menu 5: "First warming" function

This function can be used for gradual warming of new
screed.
Possible values: [OFF] or [ON]
This function does not apply by default (Installer menu
number 4: OFF by default, factory value = OFF).
Progressive warming cement slab during 21 days
period, but limited to 20°C.
Working description:
When the thermostat comes back to the normal
mode, the user sees instead of the temperature,
the remaining number of days of the progressive
warming (total duration: 21 days).
During this time, the thermostat warming cycle is
equal to 24 minutes (60 cycles per day).
Display backlight "on" duration
Setting of the display backlight.
Change the time with <
Confirm with <
To activate this option the user enters the
installer menu number 4 and selects the
configuration ('on' or 'off') then presses ok.
Function
remains active
for 21 days.
The first day, the thermostat powers
the floor heating system during 1
minute on each 24 min cycle (= 1h of
warming the first day).
The second day, the thermostat powers
the floor heating system during 2
minutes on each 24 min cycle (= 2h of
warming the second day).
>. Possible values:
Function
remains active
for 1 day.
> buttons.