Menu 9:
Adaptive function (ITCS - Intelligent Temperature
Control System). Possible values: [OFF] or [On]
Factory value: OFF
Change the setting with <
by pressing <

Menu a: "First warming" function

Possible values: [OFF] or [On]
Factory value: OFF
Menu B: running time (is the time in which the floor
warming system is in operation)
3 ': 3 minutes
5h: 5 hours
To reset this time the user has to press <
in the same time for more than 3 seconds.
Menu C: adjustable switching hysteresis
The switching hysteresis can be adjusted to extended
On/Off cycles: Adjustable: from 0.2 - 2.0°C
Factory setting. 0.5°C

7. OPEraTiOn in sTanDBy MODE

In both cases (floor or room sensing mode) the
temperature seen on the thermostat corresponds to
the room temperature.
In room sensing mode, the user sees the
temperature measured by the thermostat
(Room Temperature) In floor sensing mode, the
user sees the room temperature Floor temperature
[Installer menu n°1]
Offset [Installer menu n°2]
=
Room temperature (seen on the thermostat)
The thermostat has an 'OFF mode'. In this stand-by
mode, the floor heating is not powered at all. The
thermostat screen will display the actual measured
room temperature.
room sensing with limiter
floor regulation mode:
Possible values: from 20°C
[20.0] to 35°C [35.0]
Factory value : 27.0°C
> button.
[0..59]
7d: 7 days
[1..23]
1m: 1 month
> button. Confirm
[1..30]
[1..99]
[
>
]
35