TEMPERATURE CONTROL PANEL
NOTE: Setpoint Temperature refers to the desired tem-
perature setting.
Pressing the TEMP UP key will display the current plat-
en heater temperature providing the platen temperature
is over 440°F (227°C).
Pressing the TEMP DOWN key will display the current
auxiliary heaters temperature providing the auxiliary
heaters temperature is over 360°F (182°C).
Pressing TEMP SCALE key will switch the temperature
display between Fahrenheit (°F) and Celsius (°C).
PLATEN HEATER TEMPERATURE ADJUSTMENT
1. Turn rocker switch (power on/off) to ON and wait
for temperature display to finish the power up
sequence (Figure 6).
2. Press and hold both TEMP UP and TEMP DOWN
keys for over 1 second until the display flashes
the setpoint temperature, then release (Figure 7).
3. Press the TEMP UP key to raise the setpoint tem-
perature or press the TEMP DOWN key to lower
the setpoint temperature. The setpoint tempera-
ture will adjust 1° every 0.1 seconds.
4. Release the key when the desired setpoint is dis-
played.
NOTE: If no change is made within 5 seconds, the dis-
play will revert back to the previous setpoint.
AUXILIARY HEATER TEMPERATURE ADJUSTMENT
1. Turn rocker switch on and wait for temperature
display to finish the power up sequence
2. Press and hold both TEMP UP and TEMP SCALE
keys for over 1 second until the display flashes
the setpoint temperature, then release (Figure 8).
3. Press the TEMP UP key to raise the setpoint tem-
perature or press the TEMP DOWN key to lower
the setpoint temperature. The setpoint tempera-
ture will adjust 1° every 0.5 seconds. Continuing
to depress the key for over two consecutive sec-
onds will increase the adjustment speed 1° every
0.1 seconds.
4. Release the key when the desired setpoint is dis-
played.
NOTE: If no change is made within 5 seconds, the dis-
play will revert back to the previous setpoint.
P/N 1010747 Rev. G 11/15
VERTICAL CONTACT TOASTER
OPERATION (continued)
3. SP-A (Setpoint Auxiliary)
.
(Figure 6)
9
"Heat On" LED will blink on/off during warm-up and when
either platen or auxiliary heaters are calling for heat.
SP - P
˚F
˚C
TEMP
TEMP
TEMP
UP
DOWN
SCALE
POWER
1. SP-P (Setpoint Platen)
is displayed
SP - A
˚F
˚C
TEMP
TEMP
TEMP
UP
DOWN
SCALE
POWER
is displayed
LO
˚F
˚C
TEMP
TEMP
TEMP
UP
DOWN
SCALE
POWER
5. "LO" is displayed until
platen temperature rises
above 550°F (288°C)
* Platen setpoint temperature must be between
460°F (238°C) and 600°F (315°).
FIGURE 6. TEMPERATURE POWER UP SEQUENCE
600
˚F
˚C
TEMP
TEMP
TEMP
UP
DOWN
SCALE
POWER
2. Current Platen Temperature
setting is shown
420
˚F
˚C
TEMP
TEMP
TEMP
UP
DOWN
SCALE
POWER
4. Current Auxiliary
Temperature setting is shown
USE
∞F
∞C
TEMP
TEMP
TEMP
UP
DOWN
SCALE
POWER
6. USE is displayed when
Platen Setpoint Temperature*
is reached