Tilt Angle; Figure 6: Tilt Angle - Opticon OPL 9712 Specifications

Barcode data collector
Table of Contents

Advertisement

Tilt Angle

8.3.3.
Scanning performance is guaranteed when γ = ±20°
Conditions
Barcode Sample: OPTOELECTRONICS Test Sample
Distance:
90 mm from the edge of the data collector
Label:
Pitch, Skew Angle
PCS = 0.9, Resolution = 0.25 mm, Symbology = 9-digit Code 39,
Quiet Zone = 10 mm, N/W Ratio = 1:2.5
Dead Zone, Tilt Angle
PCS = 0.9, Resolution = 0.26 mm, Symbology = 13-digit JAN, Quiet Zone = 10 mm
Angle:
Curvature: R = ∞, Skew Angle = β +15° (for measuring Pitch Angle and Tilt Angle)