To reduce the potential for fire, keep the engine area free
of excessive grease, grass, leaves, and accumulation of dirt.
•
Never use an open flame to check the level or leakage of
fuel or battery electrolyte.
•
If the engine must be running to perform a maintenance
adjustment, keep your hands, feet, clothing, and any parts
of your body away from the engine and any moving parts.
Keep everyone away.
•
Do not use open pans of fuel or flammable cleaning
fluids when cleaning parts.
•
Do not adjust the ground speed governor. To ensure
safety and accuracy, have an Authorized Toro Distributor
check the ground speed.
•
Keep your body and hands away from pin hole leaks or
nozzles that eject high pressure fluid. Use cardboard or
paper to find leaks. Fluid escaping under pressure can
penetrate skin and cause injury requiring surgery within a
few hours by a qualified surgeon or gangrene may result.
•
If major repairs are ever needed or assistance is required,
contact an Authorized Toro Distributor.
•
To be sure of optimum performance and safety,
always purchase genuine Toro replacement parts and
accessories. Replacement parts and accessories made by
other manufacturers could be dangerous. Altering this
sprayer in any manner that may affect sprayer operation,
performance, durability, or its use, may result in injury or
death. Such use could void the product warranty.
Sound Power
This unit has a guaranteed sound power level of of 98 dBA,
which includes an Uncertainty Value (K) of 1 dBA.
Sound power level was determined according to the
procedures outlined in ISO 11094.
Sound Pressure
This unit has a sound pressure level at the operator's ear of 83
dBA, which includes an Uncertainty Value (K) of 1 dBA.
Sound pressure level was determined according to the
procedures outlined in EN ISO 11201.
Hand-Arm Vibration
Measured vibration level for right hand = 1.00 m/s
Measured vibration level for left hand = 0.90 m/s
Uncertainty Value (K) = 0.5 m/s
Measured values were determined according to the procedures
outlined in EN 1032.
Whole Body Vibration
Measured vibration level = 0.2 m/s
2
2
2
2
Uncertainty Value (K) = 0.5 m/s
Measured values were determined according to the procedures
outlined in EN 1032.