Spray Pro™ Monitor
The Spray Pro monitor displays and monitors various system
performance data such as vehicle speed and application rates.
It does not control the application rate.
SPEED
CALIBRATION
DISTANCE
SPEED
CALIBRATION
UNITS OF
SEL
MEASURE
UNITS
1. LCD screen
2. Selection dial
3. Reset, calibration button
4. Calibrate, calibration button 8. Calibration distance
Monitor Display Selection Dial
Use the dial to set the LCD screen display to the following:
Speed
Displays the ground speed in miles per hour (if the Units
of Measure is set to US or TURF) or kilometers per hour
(if the Units of Measure is set to SI).
Calibration Distance
Records the distance traveled in feet (US and TURF) or
meters (SI) used when calibrating the speed.
Speed Calibration
Alternates the display of the speed calibration value and
the recorded calibration distance at 3 second intervals.
Use this setting to adjust the speed sensor calibration.
Units of Measure
Displays the current measurement unit selection as
follows:
– US (US gallons per acre)
– SI (liters pre hectare)
– TURF (US gallons per 1000 sq ft)
APPLICATION
RATE
CALIBRATION
VOLUME
FLOW METER
CALIBRATION
WIDTH
Figure 19
5. Decrease, calibration
button
6. Increase, calibration button 10. Units of measure
7. Speed
The monitor has an LCD screen that displays the data you
select, a selection dial, and 4 buttons for calibrating the
monitor (Figure 19).
G002569
9. Speed calibration
11. Select units
12. Application rate
Application Rate
Displays the application rate in US gallons per acre
(US), liters pre hectare (SI), or US gallons per 1000 sq ft
(TURF).
Calibration Volume
Records the volume in US gallons (US and TURF) or
liters (SI) that you spray. Use this setting to calibrate the
flowmeter.
Important: In order to accurately record the volume,
be sure all three boom valves are turned on. This
sprayer cannot accurately record the tank volume
when any of the boom valves off.
Flowmeter Calibration
Alternates the display of the flowmeter calibration value
and the recorded calibration volume at 3 second intervals.
Use this setting to adjust the flowmeter calibration.
Width
Sets and displays the boom width. The default setting is
220 inches (460 cm). This is based on 4 nozzles on the
22