9.14. ELECTRICAL ELEMENT INSTALLATION (OPTIONAL)

9.14.1. INTRODUCTION

Only one 11.25kW electrical elements is available for the Mini-Caddy. This option includes all components necessary
for the installation. Instructions for installing the electrical element are provided with the electrical element.
WARNING: USE WIRING SUITABLE FOR 75 °C (NOT INCLUDED).

9.14.2. CONNECTING THE ELECTRICAL ELEMENT

OUTPUT
MODEL
(CFM)
11.25 kW
1400
WOOD
Electrical connections must conform to the wiring diagram supplied with the option.
The electrical element must be connected to the power board (See Section 17 - ELECTRICAL DIAGRAM FOR
ELECTRIC UNIT). For security reasons, the electrical element has a manual reset thermostatic sensor that is located
inside the electrical unit. If the temperature of the electric unit exceeds the high limit, the thermostatic sensor will
disengage the elements. After finding and fixing the problem that has caused the unit to overheat (static pressure too
high, fan breakdown, etc.), reactivate by pressing the red "manual reset" button on the thermostatic sensor (L-170
thermodisc)
L-170 Thermodisc RESET
28
TEMP. VAR.
TOTAL AMPERAGE
BTU/H
(OF)
67
38 400
ALIMENT.
BREAKER
CALIBRE
45
60
2
15
VOLTAGE
# OF ÉLÉMENTS
1 PHASE
4 – 3.75 kW
6
120/240
14
120
Red button manual reset