Once the RTD is installed on the support,
proceed to its connection to the link
board. Pass the RTD wires along the
furnace and bring them close to the link
board. For board connections, refer to the
wiring diagram.

9.5. SERVOMOTOR INSTALLATION AND CONNECTION

Your Mini-Caddy furnace is equipped with a servomotor. To install it, simply screw it in place in the two pre-drilled holes
on the side of the furnace using two screws as shown below.
Once installed, install the chain linking the servomotor with the air control damper as shown above. The chain must
have a set of 1/8". When there is no call for heat, the air control damper must be completely closed and the chain must
be hooked to the servomotor at the 9:15 position.