18. LINK BOARD OPTIONS CONNECTIONS

18.1. ELECTRICAL CONSUMPTION

Your Mini-Caddy furnace is able to supply electrical 24V current to control various options. The options that can be
supported are described in the table below. The maximum available 24V current is 1.66 amps (transformer 24V @
40VA). The table below shows the approximate electrical consumption of each of the options that can be installed with
your Mini-Caddy furnace. It is important to note that those consumptions were determined according to the maximum
consumption of the options tested by the manufacturer. It is possible to find on the market options having higher or
lower electrical consumption than those shown in the table below. In the event that the combined electrical
consumption of the installed options is higher than 1.66 amps, contact our after-sale service for further information.
WARNING: INCORRECT WIRING CAN DAMAGE THE LINK BOARD.
Additional 24V equipment
Air conditioning damper
Humidifier
Heat pump
Thermostat (if not battery powered)
* It is important that the sum of the electrical consumption of the installed options is not higher than 1.66 amps.

18.2. OUTDOOR PROBE

* The outdoor probe act as a switch therefore it does not consumes electrical current.
18.3. 24V ADDITIONNAL EQUIPMENT
48
Option
Approximate consumption (mA)
Current supply via additional transformer (not provided)
500
500
500
500

Advertisement