9.14. ELECTRICAL ELEMENT INSTALLATION (OPTIONAL)

9.14.1. INTRODUCTION

Two electrical elements are available for the Max Caddy: and 20Kw et 25kW. These options include all components
necessary for the installation. Instructions for installing the electrical elements are provided with the electrical element.
WARNING: USE WIRING SUITABLE FOR 75 °C (NOT INCLUDED).

9.14.2. CONNECTING THE ELECTRICAL ELEMENT

THEORETICAL
MODEL
OUTPUT
20 kW
2,100
25 kW
2,100
WOOD
2,100
Electrical connections must conform to the wiring diagram supplied with the option.
The electrical element must be connected to the power board (See Section 17 - ELECTRICAL DIAGRAM FOR
ELECTRIC UNIT). For security reasons, the electrical element has a manual reset thermostatic sensor that is located
inside the electrical unit. If the temperature of the electric unit exceeds the high limit, the thermostatic sensor will
disengage the elements. After finding and fixing the problem that has caused the unit to overheat (static pressure too
high, fan breakdown, etc.), reactivate by pressing the red "manual reset" button on the thermostatic sensor (L-170
thermodisc).
L-170 Thermodisc RESET
TEMP. VAR.
BTU/HR
O
(
F)
75
68,240
85
85,325
100
180,000
INSIDE VIEW OF ELECTRIC ELEMENT
AMPS
BREAKER
FEEDER
TOTAL
REQUIRED
GAUGE
85
125 amps
100
150 amps
5
15 amps
VOLTAGE
SINGLE PHASE
3
120/240
2
120/240
14
120
Red button manual reset
ELEMENTS
QTY
4 x 5 kW
5 x 5 kW
N/A
29