Appliance Performance - CADDY PF01302 Installation And Operating Instructions Manual

Table of Contents

Advertisement

2. APPLIANCE PERFORMANCE

Fuel type
Recommended heating area
Firebox volume
[*]
Maximum burn time
Maximum input capacity (dry cordwood)
Overall heat output rate (min. to max.)
Average overall efficiency
Delivered heat output rate (min. to max.)
Average delivered efficiency
(9)
Optimum efficiency
Average particulate emissions rate
(12)
Average CO
Average electrical power consumption
[*]
Recommended heating area and maximum burn time may vary subject to location in home, chimney draft, heat loss factors,
climate, fuel type and other variables. The recommended heating area for a given appliance is defined by the manufacturer as its
capacity to maintain a minimum acceptable temperature considering that the space configuration and the presence of heat
distribution systems have a significant impact in making heat circulation optimum.
(1)
Values are as measured per CSA B415.1-10, except for the recommended heating area, firebox volume, maximum burn time
and maximum input capacity. Performances based on a fuel load prescribed by the standard at 10 lb/ft³ and with moisture
content between 18% and 28%.
(2)
Input value at 10lb/ft³ fuel loading density and dry energy value of 8,600BTU/lb.
(3)
Overall: Radiated and delivered heat together at10lb/ft³ fuel loading density over one total burn cycle.
(4)
Efficiency based on radiated and delivered heat when allowing cycling from high to low burn to simulate thermostat demand.
(5)
Higher Heating Value of the fuel.
(6)
Lower Heating Value of the fuel.
(7)
Delivered: Remotely provided to other rooms through ducting at 10 lb/ft³ fuel loading density over one total burn cycle.
(8)
Efficiency based on delivered heat when allowing cycling from high to low burn to simulate thermostat demand.
(9)
Optimum overall efficiency at a specific burn rate (LHV).
(10)
Based on delivered heat output.
(11)
This appliance is officially tested and certified by an independent agency.
(12)
Carbon Monoxyde. Based on overall heat output at 10lb/ft³ fuel loading density.
(13)
Unless
stated otherwise, measures were taken directly at the main power source and include all electrical components present in
the appliance.
(1)
[*]
(2)
(3)
(4)
(7)
(8)
(10)(11)
(13)
Dry cordwood
500 to 1,500 ft² (46 to 139 m²)
2.3 ft³ (0.065 m³)
13 h
198,000 BTU
11,319 BTU/h to 37,053 BTU/h (3.3 kW to 10.8 kW)
(5)
75.7% (HHV)
10,849 BTU/h to 36,429 BTU/h (3.2 kW to 10.7 kW)
(5)
70.6% (HHV)
85.1%
0.841 lb/mmBTU (0.362 g/MJ)
15.61 lb/mmBTU (6.72 g/MJ)
760 Wh
(6)
81.1% (LHV)
(6)
77.2% (LHV)
5

Advertisement

Table of Contents
loading

Table of Contents