12.3. FLUE PIPE INSPECTION
The flue pipe must be inspected regularly during the heating season.
The pipe must be dissembled and cleaned.
The pipe must be examined carefully to detect any defect or damage.
The pipe can be reassembled if no defect is detected and defective pipe must be replaced immediately.
Burn only wood in this furnace.
As a combustible, well seasoned hardwood in 18" logs works best
12.4. BLOWER MOTOR MAINTENANCE
Periodic cleaning of the blower housing as well as blower and blower blades using a vacuum cleaner is necessary in
order not to affect performance and cause overheating of the latter. DO NOT OVERLUBRICATE.
12.5. FILTERS
Never use the furnace without air filters. To function as expected, controlled combustion wood burning appliance must
be maintained on a regular basis. The air filter must be cleaned and replaced regularly. Use the same size and type of
filter as the original.
12.5.1. AIR FILTER DIMENSIONS
20" X 15" Filter
12.6. DOOR GASKET MAINTENANCE
It is important to maintain the door gasket in good condition. After a while, the gasket might sag; a door adjustment
may then be required. If the door adjustment is not sufficient, replace the door gasket with a genuine one.
12.6.1. DOOR ADJUSTMENT PROCEDURE
1. Unscrew completely the locking pin (see picture below).
2. To increase the pressure of the door on the gasket, turn the handle counter clockwise; to decrease the pressure of
the door on the gasket, turn the handle clockwise until desired pressure is attained.
3. Then, screw back the locking pin about 1/4" deep and make sure you lock it in place with the nut.
13. REPLACEMENT PARTS
Your PSG furnace is designed to burn clean and requires little maintenance. It is recommended to conduct a visual
inspection at least once a month to uncover any damage to the unit. Any defect must be repaired without delay using
genuine PSG replacement parts. You can find a complete list of replacement parts in our website at
www.Caddyfurnaces.com.
Locking pin
39