No air bubbles entering system or pool
Filter empties and pump loses prime
Light bulb does not light
The ballast resets instantly on restoration of power. When the lamp restarts, it will light up orange first then turn
blue in about 10 seconds. If the UV bulb still does not illuminate 1-800-627-5886 and ask for customer service
for further instructions.
Item
Part Number
Single Unit
1.
004-402-3880-00
2.
005-402-3834-00
3.
005-402-3820-00
4.
**
5.
005-402-1384-00
6.
005-402-3361-00
7.
**
8.
**
9.
**
10.
005-402-3247-00
11.
**
12.
**
13.
**
14.
005-402-1050-00
Air Bleed
15.
006-402-3872-00
16.
004-402-3873-00
17.
005-252-3260-00
** Not available to purchase individually
TROUBLESHOOTING & SERVICE
ISSUE

CLEAR O3 PART NUMBERS

Description
Clear O3 ® Single Assembly
Lamp
Mounting Brackets (4Pk)
Ground Lug
Conduit Compression Fitting 1/2"
Tubing With Check Valve Pump Mount, & Wire Ties
Tubing 3/8" OD x 1/4" ID x 10'
Pump Mount Check Valve 1/4" NPT x barb
Wire Ties (4Pk)
Flow Meter Kit
Compression Nut 1/4" x 3/8"
Anchor #10
Screw: 10 x 3/4" PHIL PH
Clear O3 Adapter Pot Plug (Optional)
Clear O3 Air Bleed Kit (Optional)
Pressure Side Mazzei Injector Manifold
Clear O3 Mazzei Conversion Kit
Clean filter then adjust airflow needle valve
Replace check valve fitting at strainer pot
Check power to the ClearO3, if you have power and
the bulb still doesn't light up, turn off the power and
replace the bulb.