PLUMBING THE CLEAR03 WITH THE ULTRA UV AND OFF LINE
CHLORINE FEEDER USING THE VENTURI INJECTOR METHOD
When installing a Clear O3 and an Ultra UV with a Pressure Side Venturi Injector Manifold in the same pool
system it is recommended, for maximum sanitation, that the Venturi Manifold be installed after the filter followed
by the Ultra UV.
Pool systems that have erosion type chlorine/bromine feeders we recommend installing a feeder designed for
off line plumbing installations offered by several pool equipment manufacturers.
The inlet water being supplied to the feeder should be tapped between the pump discharge and the inlet to
the filter. The discharge from the feeder should return to the piping to the pool after the heater or after the last
component in the system. Follow the feeder manufacturer's instructions for installation of the feeder.
Please refer to the Plumbing Diagram Figure 1.
OFFLINE CHLORINE
FEEDER WITH FLOW KIT
CHECK
CLEAR O3
VALVE
CHECK VALVE
VENTURI INJECTOR
MANIFOLD
RETURN WATER
PUMP
FILTER
ULTRA UV
HEATER
SPA, WATER FEATURES
SUCTION FROM
POOL OR SPA
Figure 1
This piping arrangement is required to prevent air and ozone from getting into the chlorine feeder and
hampering it's performance, and to prevent chlorine from getting into the Ultra UV or other equipment and
causing damage.