PLUMBING FOR THE CLEAR03

USING THE VENTURI INJECTOR METHOD

The injector manifold must be installed in the pool's main return line after the pool filter, heater, chlorinator and
spa return. (Fig. 17) shows the basic installation. Locate the appropriate section of the return line and install
the injector manifold using PVC primer and glue on all mating surfaces. Glue in a minimum 2" return line. Water
flow arrows on the manifold must be followed and the injector needs to be facing up with the bypass down.
See Fig. 17, Fig. 18.
The Clear03 ozone suction line will hook directly up to the bottom of the Clear03 and the other end to the
injector with the check valve provided with the Clear03. No flow meter is needed or provided.
NOTE: The ClearO3 unit must be mounted at least 1' above pool water level to prevent water from
contacting electrical equipment.
CLEAR03
Fig. 17
CHECK VALVE
RETURN WATER
VENTURI INJECTOR
PUMP
FILTER
HEATER
SUCTION FROM
POOL OR SPA
Fig. 18