2. Connect a CAT-5 cable to a compatible 802.3af power source and run the cable to the
installation site. Ensure that there is sufficient slack on the cable to perform the installation
steps.
3.4.1 Wall Mounting
Wall mounting requires hanging the AP 300 Access Port along its width or length using the pair of
slots on the bottom of the unit. The AP 300 can be mounted onto any plaster, wood, or cement wall
surface using the provided wall anchors, when necessary. The illustration shows a lengthwise mount.
3.4.1.1 Wall Mount Hardware
• Two Phillips pan head self-tapping screws
• Two wall anchors
• Safety wire (recommended) and security cable (optional)
In the event that the original mounting screws are lost, the following screws
can be used instead: (ANSI Standard) #6-18 x 0.875in. Type A or AB Self-
Tapping Screw, or (ANSI Standard Metric) M3.5 x 0.6 x 20mm Type D Self-
Tapping Screw
3.4.1.2 Wall Mount Procedure
1. Orient the case on the wall by its width or length.