  • Page 3: Overview

    OVERVIEW ® The iConverter Network Management Module (NMM) is the heart of the iConverter management system. It features a 32-bit, high performance RISC microprocessor executing a realtime operating system. It supports the SNMP and Telnet protocols and is capable of controlling up to 19 managed chassis. The NMM delivers Operations, Administration and Maintenance (OAM) services for carrier-class network access with comprehensive provisioning and network monitoring.
  • Page 4: Port Structure

    PORT STRUCTURE OVERVIEW The Network Management Module front panel provides the access to the Management ports. Management can be accessed through the serial port or the UTP port. The module features a backplane Ethernet port for connectivity to adjacent modules. Daisy Chain Port UTP Management Port 2.1.1...
  • Page 5: Utp Management Port

    The illustration below shows how multi-chassis are managed using Omnitron’s NetOutlook Management Software. From the chassis view screen, each of the chassis are available. Multi-chassis configuration can also be managed through the serial console port. From the Chassis Selection section of screen, each of the chassis connected together are available. See Section 4.0 for detailed menu screens.
  • Page 6 “A” Data bus “B” Data bus “A” Data bus “B” Data bus 9 10 11 12 13 14 15 16 17 18 19 19-Module Chassis 5-Module Chassis Managed Power Chassis iConverter ™ by Omnitron Systems Technology, Inc. “A” Data bus 2-Module Chassis Page 6...
  • Page 7 The backplane data bus supports Out-of-Band Management and In-Band Management configurations. Out-of-Band Management Out-of-Band Management is available by directly connecting the Network Management Station (NMS) to the UTP port on the front of the NMM. This isolates the management traffic from the rest of the traffic in the chassis.
  • Page 8: Installation Procedure

    INSTALLATION PROCEDURE OVERVIEW The following steps outline the installation and configuration procedures for the NMM. Refer to the specified sections for detailed instructions. • Configuring Switches (Section 3.2) • Installing the Module and Connecting the UTP Cable (Section 3.3) • Configure the Module via Command Line Interface (Section 3.4) •...
  • Page 9: Configure The Module Via Command Line Interface

    CONFIGURE THE MODULE VIA COMMAND LINE INTERFACE To configure, attach the NMM to a DB-9 serial (RS-232) equipped computer with terminal emulation software such as HyperTerminal. Using a standard serial cable, connect the serial port of the PC and the Serial Console Port of the NMM.
  • Page 10 Management Options screen. If a password has been set, the Password Entry screen will be displayed. Type the password and press <ENTER>, the NMM will respond with the Management Options screen. Omnitron Systems Technology, Inc. Copyright 2001-2007 OST, Inc. ------------------------------------------------------------------------------...
  • Page 11: Setting Ip And Control Preferences

    3.4.1 Setting IP and Control Preferences An IP address is required for the SNMP or Telnet access. The factory default setting is 192.168.1.220. The IP address can be configured manually or automatically as a DHCP client. 3.4.1.1 Setting IP Parameters Manually To manually configure the IP address and control parameters, select 3 from the Management Options screen.
  • Page 12 3.4.1.2 Setting IP Parameters as DHCP Client To configure the IP automatically as a DHCP client, select 9 from the Management Options screen. The Other Networking Features screen will appear. Management Options Network Management Chassis and Module Management Set Module Identifier Management Module Preferences IP and Control Preferences SNMP Preferences...
  • Page 13 To set the Chassis Name, select 5 at the IP and Control Preferences screen, press <ENTER> and follow the instructions to enter the chassis name. IP and Control Preferences Screen Set IP Set Subnet Mask Set Gateway Chassis Number Chassis Name (also sysName) Enable/Disable TELNET Enable/Disable FTP Enable/Disable Soft Switch Reload...
  • Page 14: Setting Snmp Preferences

    3.4.2 Setting SNMP Preferences To set the SNMP Preferences for the NMM, select 4 from the Management Options screen, press <ENTER> to enter the SNMP Preferences screen. SNMP Preferences Screen Chassis Number 1: sysContact 2: sysLocation 3: SNMP Writes SNMP v1/v2c ------------------------------------------------------------------- 4: Read Community 5: Write Community 6: Agent...
  • Page 15 The module supports the three levels of Authentication and Encryption (Security Levels) for User 1 and User 2; noAuthNoPriv, authNoPriv and authPriv. noAuthNoPriv uses username for authentication, authNoPriv provides authentication based on the HMAC-MD5 algorithm and authPriv provides DES 56-bit encryption based on the HMAC-MD5 algorithm. To set User 1 security, select 10 at the SNMP Preferences screen, press <ENTER>...
  • Page 16: Management Support

    3.4.3 Management Support 3.4.3.1 VLAN The NMM Management Processor can independently transmit and receive Management Data with an IEEE 802.1Q tag. To enable and configure this feature, type 9 from the Management Options screen to access the Other Networking Features screen. Other Networking Features Screen 1: Enable/Disable DHCP Client 2: Enable/Disable Keep Alive Trap...
  • Page 17 switch settings, then the module’s hardware settings take effect. To set the Soft-switch Reload function, select 8 at the IP and Control Preferences screen, press <ENTER> and then follow the screen prompts to change the setting. IP and Control Preferences Screen Set IP Set Subnet Mask Set Gateway...
  • Page 18: Access The Nmm Remotely

    3.4.5 Access the NMM Remotely Remote access to the NMM is provided via SNMP, Telnet, FTP or an external serial modem connected to the Serial Console Port. 3.4.5.1 Accessing the NMM via NetOutlook (SNMP) The NMM can be remotely accessed by SNMP-client software such as Omnitron’s NetOutlook SNMP Management Software or third-party SNMP management software.
  • Page 19 IP and Control Preferences Screen Set IP Set Subnet Mask Set Gateway Chassis Number Chassis Name (also sysName) Enable/Disable TELNET Enable/Disable FTP Enable/Disable Soft Switch Reload TELNET Password 10: FTP Password 11: Serial Password Enter Choice, Management Options Screen(0), (H)elp, E(x)it >6 Disable TELNET (Y/N)?>...
  • Page 20: Verify Operation

    3.4.5.4 Updating the NMM Firmware via FTP Using an FTP application, upload the new firmware into the FTP root directory of the NMM. When the file transfer is complete, the NMM verifies the file and then automatically restarts with the newly loaded firmware.
  • Page 21: Module Status

    MODULE STATUS OVERVIEW The Module status screen provide information on the NMM. The Module status screen is accessible by selecting the module slot number from the Chassis View screen. To access the Module status screen, select 1 at the Management Options screen, press <ENTER>. The Chassis Selection screen will be displayed. From the Chassis Selection screen, select the number of the chassis where the desired module resides.
  • Page 22 Module - iConverter NMM Identifier - Chassis Number Slot Number Model Number 8000-0 Serial Number xxxxxxxx Manufacturing Date xxxxxxxx Hardware Revision Software Revision 1: Power 2: Power Supply 1 3: Power Supply 2 4: Power Supply 3 5: Master(on)/Slave 6: Mgmt Activity 7: Not Available 8: Not Available 9: UTP Link...
  • Page 23: Nmm Specifications

    NMM SPECIFICATIONS Protocols Copper Connectors Controls LED Displays Supported MIBs Dimensions Weight Power Requirements Compliance Operating Temp. - Standard - Wide Temp. Range Storage Temp Humidity (non-condensing) Altitude MTBF (hrs) IP, UDP, SNMPv1, SNMPv2c, SNMPv3, TCP, ARP, ICMP, Telnet, FTP, 802.3ah RJ-45, DB-9 UTP Crossover, Frontplane/Backplane Pwr, Pwr Supply (3), Management Link,...
  • Page 24: Troubleshooting Guide

    TROUBLESHOOTING GUIDE OVERVIEW The NMM module has several LED indicators available to assist in the determination of problems. Refer to Section 3.5, Verify Operation, for LED definitions. 6.1.1 Power Issues Problem: The Power LED does not illuminate after installation is complete or no LED indicators are ON Possible Causes: A.
  • Page 25: Warranty

    WARRANTY This product is warranted to the original purchaser against defects in material and workmanship for a period of TWO YEARS from the date of shipment. A LIFETIME warranty may be obtained by the original purchaser by REGISTERING this product with Omnitron within 90 days from the date of shipment. TO REGISTER, COMPLETE AND MAIL OR FAX THE ENCLOSED REGISTRATION FORM TO THE INDICATED ADDRESS.