3.4

CONFIGURE THE MODULE VIA COMMAND LINE INTERFACE

To configure, attach the NMM to a DB-9 serial (RS-232) equipped computer with terminal emulation
software such as HyperTerminal. Using a standard serial cable, connect the serial port of the PC and the
Serial Console Port of the NMM. This is a standard asynchronous DCE serial interface. The pin-outs are
illustrated below.
Start HyperTerminal and select the correct COM Port in the HyperTerminal "Connect To:" window.
Set the PC's serial port to the following:
Bits Per Second:
Stop Bits:
Data Bits:
Parity:
Hardware Flow Control:
Power the chassis containing the NMM and press <ENTER> to bring up a command line prompt on the
attached PC.
The module is configured with the following defaults:
IP
IP Address:
IP Subnet Mask:
Passwords
Serial:
FTP:
Telnet:
SNMPv1/v2c Communities
READ:
WRITE:
SNMPv3 Parameters
User 1 name (read only):
User 2 name (read/write):
User 1 Privacy pwd:
User 2 Privacy pwd:
DB-9 Female
RD
2
5
TD
3
GND
5
9
RTS
7
Serial Connector Pin Outs
57,600
1
8
NONE
NONE
192.168.1.220
255.255.255.0
No password assigned
No password assigned
public
public
public
guest
admin
publicguest
privateadmin
Page 9
1
6
User 1 Authen pwd:
User 2 Authen pwd:
publicguest
privateadmin