Omnitron Systems Technology Omnitron 8000-0 User Manual page 12

Network management module
Table of Contents

Advertisement

3.4.1.2
Setting IP Parameters as DHCP Client
To configure the IP automatically as a DHCP client, select 9 from the Management Options screen. The
Other Networking Features screen will appear.
Management Options
Network Management
1:
Chassis and Module Management
2:
Set Module Identifier
Management Module Preferences
3:
IP and Control Preferences
4:
SNMP Preferences
5:
Abandon Preference Changes
6:
Save Preference Changes
7:
Restore to Factory Defaults
8:
Restart Management Module
9:
Other Networking Features
Management Module Maintenance
10: Firmware Update
11: Set Date/Time
IP Address
= 192.168.1.220
Chassis Number = 1
Enter Choice, (H)elp, E(x)it > 9
Other Networking Features Screen
1: Enable/Disable DHCP Client
2: Enable/Disable Keep Alive Trap
3: Keep Alive Trap interval (10-600 secs)
4: Serial Baud Rate
5: Enable/Disable Remote OAM
6: Enable/Disable IP Protocol
7: Enable/Disable VLAN Support
8: VLAN ID (0-4095)
9: VLAN Priority (0-7)
Enter Choice, Management Options Screen(0), (H)elp, E(x)it >
To enable DHCP client, select 1 at the Other Networking Features screen and follow the screen prompts
to enable DHCP.
To save the new values, select 0 and press <ENTER> to return to the Management Options screen, then
select 6 and press <ENTER> to Save Preference Changes.
3.4.1.3
Setting the Chassis Number and Name
A Chassis Name, or sysName, can be assigned to the NMM for identification to the SNMP management
software. The name can be any 1-32 character alphanumeric string.
The Chassis Number can remain as 1 (factory default) when the NMM is installed without another management
module (a media converter with integrated management such as the 10/100M) in the same chassis. When the
NMM is installed in the same chassis with another management module, they must all be set to the same Chassis
Number.
To set the Chassis Number, select 4 at the IP and Control Preferences screen, press <ENTER> and follow
the instructions to enter the chassis number.
iConverter, Serial Agent
iConverter, Serial Agent
Disabled
Disabled
10
57600 bps
Enable
Enable
Disabled
2
7
Page 12

Advertisement

Table of Contents
loading

This manual is also suitable for:

Iconverter

Table of Contents