  • Page 1 ® iConverter 2-Module Power Chassis User Manual 140 Technology Dr., #500 Irvine, CA 92618 USA Phone: (949) 250-6510; Fax: (949) 250-6514 Page 1...
  • Page 2 To avoid electrical shock, do not perform any servicing of this module other than that contained in the operating instructions, unless you are qualified and certified to do so by Omnitron Systems Technology, Inc. Caution All user-required operations can be performed without opening the chassis. Never attempt to open or remove the cover or tamper with the chassis.
  • Page 3: General Description

    2-Module Power Chassis User Manual 1. 0 GENERAL DESCRIPTION iConverter 2-Module Power Chassis is powered by a single internal universal iConverter AC or DC power supply and can accommodate up to two media converters. It is ideal for enterprise Local Area Network (LAN) or Metropolitan Area Network (MAN) applications where remote management and explicit demarcation between the service provider’s equipment and customer’s equipment is required.
  • Page 4 A printed circuit board which is permanently mounted inside the chassis and is populated with receptacle connectors into which modules are inserted. Module iConverter plug-in card positioned into a slot location and inserted into a backplane connector. Module-Guide A mechanical channel guiding module insertion into a backplane connector.
  • Page 5 VLANs can be used to separate the customer data from the management data. This application uses an iConverter 10/100M module for media conversion and management and a 4TxVT 4-Port 10/100 switch module for added customer connectivity.
  • Page 6 1.5.2 Out-of-Band Managed 4-Port Switch Application Fig 4. Depicts a typical managed switch application. This application uses a 4TxVT 4-Port 10/100 switch module and an iConverter Network Management Module (NMM) for management. Both modules are plugged into the 2-Module chassis.
  • Page 7: Site Preparation And Installation

    3.2 AC Powered Chassis Mounting Attach the AC power cords to the back of the Power Receptacle and plug into the AC outlet. Any installed iConverter modules will illuminate the power LED. Fig. 6 Rear of 2-Module Chassis with Power Cord 3.3 DC Powered Chassis Site Preparation...
  • Page 8 WARNING REGARDING EARTHING GROUND: This equipment shall be connected to the DC supply system earthing electrode conductor or to a bonding jumper from an earthing terminal bar or bus to which the DC supply system earthing electrode is connected. This equipment shall be located in the same immediate area (such as adjacent cabinets) as any other equipment that has a connection between the earthed conductor of the same DC supply circuit and the earthing conductor,...
  • Page 9 14 AWG gauge minimum. Cut the power cable to the length required. Strip approximately 3/8 of an inch of insulation from the power cable wires. Connect the power cables to the iConverter Chassis by fastening the stripped ends to the DC power connector.
  • Page 10: Specifications

    4.0 SPECIFICATIONS 2-Module AC 2-Module AC 2-Module DC 2-Module DC Chassis Type 8.5 watts 16.5 watts 6.6 watts 16.5 watts Model Number Standard 8230-0 8231-0 8235-0 8236-0 Dying Gasp 8230-1 8231-1 8235-1 8236-1 Module Capacity Power Supply Fixed Internal Capacity Input Power 100 to 240VAC, 100 to 240VAC,...
  • Page 11: Customer Support Information

    5.0 CUSTOMER SUPPORT INFORMATION If you encounter problems while installing this product, contact Omnitron Technical Support: Phone: (949) 250-6510 Fax: (949) 250-6514 Address: Omnitron Systems Technology, Inc. 140 Technology Dr., #500 Irvine, CA 92618, USA Email: support@omnitron-systems.com URL: www.omnitron-systems.com Page 11...