Fiber Type
FlexPoint
GX/T
SFP
10/100/1000 UTP to 100/1000X
MM
Ethernet Media Converter
SM
SM
User Manual
SM
SM
SM
SM-SF
1310/1550
SM-SF
1550/1310
SM-SF
1310/1550
SM-SF
1550/1310
Power Adapter Kits (-x):
-0 = No power adapter included
-1 = 110-120 VAC/60 Hz (US plug)
-2 = 100-240 VAC/50-60 Hz (IEC plug, no power cord)
For other power and fiber configurations, contact the factory.
DESCRIPTION:
1
62.5/125µm, 100/140µm multimode fiber up to 220m, 50/125µm
multimode fiber up to 550m. Refer to the fiber cable manufacturer for
The FlexPoint GX/T is a 10/100/1000BASE-T UTP to
multimode distance specifications.
1000BASE-X fiber media converter that supports jumbo
Single-Fiber converters must be used in pairs. The Tx wavelength
frames up to 10,240 bytes. The GX/T features Small
on one end has to match the Rx wavelength on the other.
Form Pluggable (SFP) transceivers that support both
POWER ADAPTER NOTICE:
100BASE-FX and 1000BASE-X for interoperability with
Gigabit and Fast Ethernet fiber equipment.
1. This product should only be used with Omnitron Supplied
Power Unit model numbers 9113-PS [US] or 9115-PS
Both the fiber port and the UTP port support auto-
[Universal].
negotiation, an IEEE standard which defines how all the
communicating devices automatically perform their
2. When used in a standalone configuration, this product
configuration functions.
must be used with a Listed Direct Plug-In Power Unit
marked "Class 2" and rated at 9VDC, 1 Amp.
The auto-negotiation feature can be disabled on both ports
(for manual configuration) using DIP-switches on the
NOTE: If mounting with a safety ground attachment,
product. This is useful in a situation where the GX/T is
use the safety ground screw at the rear of the unit.
connected to a non-negotiating device and the configuration
NOTE: Remove safety ground screw when installing
parameters must be set manually.
the module in the 14-Module Chassis or when using
Page 1
setting the DIP-switch to "Off" causes the unit to advertise
UTP MODES
no Pause capability. In the manual mode, this DIP-
SW3
switch determines the Symmetrical Pause behavior.
AN/MAN
Loopback "Off/On" DIP-Switch:
Setting this DIP-switch "On" enables loopback on the
AN
fiber and UTP ports (see Figure 1).
Link Modes:
AN
See the following table for configuring link modes:
AN
SW9
SW10
Result
"LS/LP"
"RFD/Normal"
AN
LS
Normal
Enables Link Segment mode (LS).
AN
LP
Normal
Enables Link Propagate mode (LP).
Enables Remote Fault Detection mode plus
LS
RFD
AN
Link Segment mode (RFD+LS).
Enables Remote Fault Detection mode plus
LP
RFD
MAN
Link Propagation mode (RFD+LP).
NOTE: RFD is only available when the fiber port is
operating in manual mode.
MAN
REMOTE FAULT
Each port will generate an "IEEE remote_fault indicator"
when the incoming signal to the port is lost. When a port
MAN
is configured for auto-negotiation, it will set the remote
MAN
fault bit "high" in the AN advertisement when the port
MAN
detects a loss of incoming signal. See LED Indicators
MAN
table on page 9 for specifics on how the unit reports the
When the module is configured for auto-negotiation, the module will advertise in
detection of this signal.
the order shown in the parenthesis.
When the fiber port is operating in 100BASE-FX, a loss of
incoming signal will cause the port to generate a Far-End-
Fault indicator pattern. See LED Indicators table on page
9 for specifics on how the unit reports the detection of
this signal.
Page 7
it with the DC-DC Converter (Model # 4384)
Connector Type
Distance
ST
SC
SFP
-
-
-
4719-x
Before inserting the Power Adapter, verify
220 / 550m
1
4706-x
4700-x
-
that the power on the unit is appropriate
12km
4707-x
4701-x
-
for your AC line voltage source.
34km
-
4702-x
-
-
4703-x
-
80km
110km
-
4704-x
-
INSTALLATION PROCEDURE
140km
-
4705-x
-
1.) Configure the appropriate FlexPoint GX/T DIP-Switch
20km
-
4710-x
-
settings.
20km
-
4711-x
-
2.) Connect the UTP port via a Category 5 or better cable
40km
-
4712-x
-
to a 10BASE-T, 100BASE-TX or 1000BASE-T Ethernet
device.
40km
-
4713-x
-
3.) When using fixed fiber port models, connect the
appropriate multimode or single-mode fiber cable to the
fiber port of the installed module. It is important to ensure
that the transmit (Tx) is attached to the receive side of
the device at the other end and the receive (Rx) is attached
to the transmit side. Single-fiber (SF) media converter
models operate in pairs. The Tx wavelength must match
the Rx wavelength at the other end and the Rx wavelength
must match the Tx wavelength at the other end.
4.) When using a GX/T SFP model, insert the SFP Fiber
transceiver into the Port 1 SFP receptacle on the GX/T.
NOTE: The release latch of the SFP Fiber transceiver
must be in the closed (up) position before insertion.
LOOPBACK
The FlexPoint GX/T has the capability to provide loopback
to aid in installation and maintenance. A DIP-switch is
used to enable loopback on the module (see page 7).
Figure 1 shows the module in normal and loopback modes.
Page 2
LED INDICATORS
SW4
SW5
SW6
UTP Mode of Operation
LED Function
Color
"Legend"
10/100/
10/100
FDx/HDx
1000
Power / Test
1000
NA
FDX
Configured for Auto Negotiation.
Green
"Power"
(1000F, 1000H, 100F, 100H, 10F,
10H)
F/O AN
Green
1000
NA
HDX
Configured for Auto Negotiation.
"F/O-Auto-Neg"
(1000H, 100F, 100H, 10F, 10H)
10-100
100
FDX
Configured for Auto Negotiation.
(100F, 100H, 10F, 10H)
F/O Speed 100*
Green
"F/O-100"
10-100
100
HDX
Configured for Auto Negotiation.
(100H, 10F, 10H)
10-100
10
FDX
Configured for Auto Negotiation.
(10F, 10H)
10-100
10
HDX
Configured for Auto Negotiation.
F/O Speed 1000
(10H)
Green
"F/O-1000"
1000
NA
FDX
Configured for Auto Negotiation.
(1000F)
When the port is set to 1000, it is
UTP Duplex
Green
always in AN mode.
"UTP-FDX"
1000
NA
HDX
Configured for Auto Negotiation.
UTP AN
Green
(1000H)
"UTP-Auto-Neg"
When the port is set to 1000, it is
UTP Speed 100
always in AN mode.
Green
"UTP-100"
10-100
100
FDX
Port forced to 100 FDX
10-100
100
HDX
Port forced to 100 HDX
UTP Speed 1000
Green
"UTP-1000"
10-100
10
FDX
Port forced to 10 FDX
10-100
10
HDX
Port forced to 10 HDX
UTP Speed 10
"UTP-100"
Green
+
"UTP-1000"
"UTP Auto-Neg"
+
"UTP-100"
Green
+
"UTP-1000"
*SFP models only
Page 8
FlexPoint GX/T
RX
TX
WARNING!
UTP
Fiber
TX
RX
Normal Mode
Figure 1: Loopback Mode
LINK MODES
In order to accommodate different user needs, the GX/T
supports four different link modes (see Fig. 2).
In Link Segment (LS), a port transmits a Link signal
independently of any received Link at any other port. For
example, the UTP transmits a Link regardless of the fiber
receiving a Link [Fig. 2(a) & (b)].
In Link Propagate (LP), a port transmits a Link signal only
when receiving a Link at its other port. For example, the
UTP transmits a Link only when receiving a Link at the
fiber port [Fig. 2(c)].
In Remote Fault Detection + Link Segment (RFD+LS),
the fiber port transmits a Link signal only when receiving
a Link at the fiber port. As a result, fiber faults (no Link
received at the fiber) are looped-back and can be reported
to the network core [Fig. 2(d)].
In Remote Fault Detection + Link Propagate (RFD+LP),
the UTP port transmits a Link signal only when receiving
a Link at the fiber port. The fiber port transmits a Link
signal only when receiving Link signals at both the fiber
port and the UTP port. As a result, fiber faults (no Link
received at the fiber) are propagated forward and looped
back for fault reporting at both the network core and the
customer location [Fig. 2(e)].
NOTE: Connecting two converters with both set to RFD
mode is not supported and will cause a "deadly embrace"
lockup.
Page 3
Page 4
SPECIFICATIONS
Model Type
On / Blinking State
Off State
On: Module has power
Protocols
10BASE-T, 100BASE-TX, 1000BASE-T, 100BASE-FX,
No power
Blinking: Module in loopback
mode
Frame Size
10,240 byte max. frame size
On: Fiber port configured for AN
Port configured for
Blinking: Fiber port configured for
manual negotiation
UTP Cable
RJ-45, Category 5 and higher
AN but in manual mode
On: Fiber port linked at 100Mbps
Multimode: 50/125, 62.5/125, 100/140µm
Fiber Cables
Blinking (10Hz): Link activity at
Single-mode: 9/125µm
Not connected at
100Mbps
100Mbps
UTP Connectors
Blinking (1Hz): Signal detected
but port unable to establish a link
Fiber Connectors
On: Fiber port linked at 1000Mbps
Blinking (10Hz): Link activity at
Fiber: Auto-Neg, 1000, 100
1000Mbps
DIP-Switches
UTP: Auto-Neg, 10, 100, 1000, FDX/HDX, Pause En/Dis
Not connected at
Loopback, Link Seg, Link Prop, Remote Fault Det.
1000Mbps
Blinking (1Hz): Signal detected
but port unable to establish a link
Power, Fiber AN, Fiber Speed/Activity, UTP Speed/Activity,
Pattern Blinking: AN remote Fault
LED Displays
bit detected
Dimensions
W: 3.0" x D: 4.0" x H: 1.0"
Half-Duplex
On: UTP port in Full-Duplex
Weight
6 oz. (without power adapter)
On: UTP port configured for AN
Port configured for
Blinking: UTP port configured for
manual negotiation
Compliance**
UL, CE, FCC Class A
AN but in manual mode
Not connected at
On: UTP port linked at 100Mbps
100Mbps
Blinking (10Hz): Link activity
Power
Nominal Voltage:
On: UTP port linked at 1000Mbps
Requirements
Not connected at
Voltage Range:
1000Mbps
Blinking (10Hz): Link activity
Nominal Power:
Maximum Power:
On: UTP port linked at 10Mbps
Blinking (10Hz): Link activity
Temperature
Not connected at
10Mbps
Pattern Blinking: (1Hz): Detecting
Humidity
5 to 95% (non-condensing)
"remote_fault" (AN) on UTP port
Altitude
Blinking (1Hz): Unable to establish
Module without Power Adapter: 900,000
-
MTBF (Hours)
AN link on the UTP port
Module with Power Adapter -1: 250,000
Module with Power Adapter -2: 100,000
Page 9
Page 10
LS
LS
Fiber
RX
TX
(a)
UTP
UTP
Fiber
Fiber
TX
RX
Switch 1
Converter A
Converter B Switch 2
Loopback Mode
LS
LS
(b)
Switch 1
Converter A
Converter B Switch 2
LP
LP
(c)
Switch 1
Converter A
Converter B Switch 2
LP
RFD+LS
(d)
Switch 1
Converter A
Converter B Switch 2
RFD+LP
LP
(e)
Switch 1
Converter A
Converter B Switch 2
LED On
LED Off
LED Status depends on connected device
Figure 2: Link Modes
Page 5
Warning
The operating description in this Instruction Manual is for
GX/T
use by qualified personnel only. To avoid electrical shock,
IEEE 802.3
do not perform any servicing of this unit other than that
1000BASE-X
contained in the operating instructions, unless you are
qualified and certified to do so by Omnitron Systems
Technology, Inc.
Caution
All user-required operations can be performed without
opening the unit. Never attempt to open or remove the
RJ-45
cover or tamper with the unit.
ST, SC, LC (SFP)
Warranty
This product is warranted to the original purchaser against
defects in material and workmanship for a period of TWO
YEARS from the date of shipment. A LIFETIME warranty may
Full/Half-Duplex
be obtained by the original purchaser by REGISTERING this
product with Omnitron within 90 days from the date of shipment.
TO REGISTER, COMPLETE AND MAIL OR FAX THE
REGISTRATION PORTION OF THIS INSTRUCTION
MANUAL TO THE INDICATED ADDRESS. Or you may
Barrel
Molex
register
your
product
on
the
Connector
Connector
http://www.omnitron-systems.com. During the warranty
9VDC
5VDC
period, Omnitron will, at its option, repair or replace a product
5.0 to 32.0VDC
5.0 to 32.0VDC
which is proven to be defective.
0.3A @ 9VDC
0.5A @ 5VDC
1A @ 9VDC
0.75A @ 5VDC
For warranty service, the product must be sent to an Omnitron
0 to 50
o
C
designated facility, at Buyer's expense. Omnitron will pay the
shipping charge to return the product to Buyer's designated
US address using Omnitron's standard shipping method.
-100m to 4000m
Limitation of Warranty
The foregoing warranty shall not apply to defects resulting
from improper or inadequate use and/or maintenance of
the equipment by Buyer, Buyer-supplied equipment, Buyer-
supplied interfacing, unauthorized modifications or
tampering with equipment (including removal of equipment
Page 11
DIP-SWITCHES
F/O Manual/Auto "MAN/AN" DIP-Switch:
Setting this DIP-Switch to P1 Auto-Negotiate "AN" (factory
UTP
setting) enables the Fiber Port to determine duplex mode
automatically. If the connected device cannot provide
the proper signal to indicate its own mode of operation,
this DIP-Switch should be set to P1 Manual "MAN." This
feature allows connections with legacy devices that do
not support auto-negotiation.
NOTE: When the fiber port is in Manual Mode, a link-up
may not occur with other devices. Both devices must be
set to the same mode (either Manual or Auto-Negotiate) for
the link-up to occur.
When set to auto-negotiation, the fiber port will
automatically reconfigure to manual mode when an auto-
negotiation connection cannot be established.
F/O Speed "100/1000" DIP-Switch:
The GX/T supports 100BASE-FX and 1000BASE-X SFPs.
This DIP-switch is used to configure the unit for the
speed of SFP used. Setting this DIP-switch to "1000"
enables the fiber port is accept 1000BASE-X SFPs. Setting
this DIP-switch to "100" enables the fiber port to accept
100BASE-FX SFPs. This DIP-switch is only available on
the SFP model.
This DIP-switch is ignored when using Omnitron branded
SFPs. The GX/T automatically configures the fiber port
to the correct speed.
UTP Configuration DIP-Switches:
See the UTP Modes table on page 8.
Pause "On/Off" DIP-Switch:
In auto-negotiation mode, setting this DIP-switch to "On"
allows the unit to advertise as Symmetrical and
Asymmetrical Pause capability. In auto-negotiation mode,
Page 6
cover by personnel not specifically authorized and certified
by Omnitron), or misuse, or operating outside the
environmental specification of the product (including but
not limited to voltage, ambient temperature, radiation,
unusual dust, etc.), or improper site preparation or
maintenance.
No other warranty is expressed or implied. Omnitron
specifically disclaims the implied warranties of
merchantability and fitness for any particular purpose.
Exclusive Remedies
The remedies provided herein are the Buyer's sole and
exclusive remedies. Omnitron shall not be liable for any
direct, indirect, special, incidental, or consequential
damages, whether based on contract, tort, or any legal
theory.
TECHNICAL SUPPORT:
For help with this product, contact our Tech. Support:
Phone:
(949) 250-6510
internet
at
Fax:
(949) 250-6514
Address:
Omnitron Systems Technology, Inc.
140 Technology Drive, #500
Irvine, CA 92618 USA
E-mail:
support@omnitron-systems.com
URL:
http://www.omnitron-systems.com
Form: 040-04700-001A 8/08
Page 12

Advertisement

loading
Need help?

Need help?

Do you have a question about the 10/100/1000 UTP to 100/1000X Ethernet Media Converter FlexPoint GX/T and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

Flexpoint gx/t