3.4.1

Setting IP and Control Preferences

An IP address is required for the SNMP or Telnet access. The factory default setting is 192.168.1.220. The
IP address can be configured manually or automatically as a DHCP client.
3.4.1.1
Setting IP Parameters Manually
To manually configure the IP address and control parameters, select 3 from the Management Options
screen. The IP and Control Preferences screen will appear.
IP and Control Preferences Screen
1:
Set IP
2:
Set Subnet Mask
3:
Set Gateway
4:
Chassis Number
5:
Chassis Name (also sysName)
6:
Enable/Disable TELNET
7:
Enable/Disable FTP
8:
Enable/Disable Soft Switch Reload
9:
TELNET Password
10: FTP
Password
11: Serial Password
Enter Choice, Management Options Screen(0), (H)elp, E(x)it >
To configure the IP address of the NMM, select 1 at the IP and Control Preferences screen, and press
<ENTER>. Backspace over the existing value, type the new value (in x.x.x.x format), and press <ENTER>.
To configure the subnet mask of the NMM, select 2 at the IP and Control Preferences screen, and press
<ENTER>. Backspace over the existing value, type the new value (in x.x.x.x format), and press <ENTER>.
To configure the gateway of the NMM, select 3 at the IP and Control Preferences screen, and press
<ENTER>. Backspace over the existing value, type the new value (in x.x.x.x format), and press <ENTER>.
To save the new values, select 0 and press <ENTER> to return to the Management Options screen, then
select 6 and press <ENTER> to Save Preference Changes.
iConverter, Serial Agent
192.168.1.220
255.255.255.0
192.168.1.1
1
NMM
Enabled
Disabled
Disabled
*****