2.3 Power Supply Troubleshooting
Main Battery
Error code
20h
21h
22h
23h
24h
25h
Second Battery
Error code
30h
31h
32h
33h
34h
35h
S3V output (P60)
Error code
40h
45h
2-10
Meaning
Overvoltage is detected. (This is not supported.)
Main battery charge current is over 7.00A.
Main battery discharge current is over 0.5A when there is no load.
Main battery charge current is over 3.9A when AC adapter is not
connected.
Abnormal current has been sensed 0[A].
Main battery charge current is over 0.3A.
Meaning
Overvoltage is detected. (This is not supported.)
Second battery charge current is over 7.00A.
Second battery discharge current is over 0.5A when there is no load.
Second battery charge current is over 3.1A when AC adapter is not
connected.
Abnormal current has been sensed 0[A].
Second battery charge current is over 0.3A.
Meaning
S3V voltage is 3.14V or less when the computer is powered on/off.
S3V voltage is 3.14V or less when the computer is booting up.
(CV support)