Insinger USN-72 Technical Manual page 42

Table of Contents

Advertisement

Part
3: OPERATION
gauge
8
Drain valves
8
Operation
3.2 Description of Operator Controls and Indicators (Cont.)
dial
Ball valves
(shown closed)
Placard
-~
CONTROL
@
Inlet water
supply valve
0
Inlet water
supply valve
TYPE
Ball valve
(shown closed)
Ball valve
(shown open)
@
Inlet water
supply valves
Ball valves
(shown closed)
@
water level
gauges
Sight glass
8
Tank water
temperature
gauges
Scaled
thermometer
dial
@
Final rinse
pressure gauge
0-60
PSI
gauge
3
Final rinse
temperature
Scaled
thermometer
FUN CTl ON
Connects incoming water supply
for the booster.
Connects incoming water supply for
the tank fills.
Controls manual fill to wash tank.
Controls manual fill to rinse tank.
Indicates water level in wash and
rinse tank. Water line visible in
center of glass indicates correct
water level in tank.
Indicates water temperature in
wash and rinse tanks.
Wash = 150°F minimum.
Rinse = 160°F minimum.
Indicates final rinse water pressure
during the final rinse.
20-22
PSIG minimum flow pressure.
Indicates final rinse temperature
during the final rinse.
180-1
95°F optimum range.
Controls draining
of
wash and rinse
tanks.
Complete operation quide to
machine (located on load end
of machine
on
front panel under
wash gauge next to wash door)
Table 3.2
Controls and Indicators
Dishwasher and Booster

Advertisement