Description Of Operator Controls And Indicators; Figure 3.1 . Operator Controls Remote Control Cabinet - Insinger USN-72 Technical Manual

Table of Contents

Advertisement

Part
3: OPERATION
TYPE
Selector
Red pilot
Green
Pushbutton
Red
pushbutton
3.2
Description of Operator Controls and Indicators
3.2.1 Remote Control Cabinet
FUNCTION
Controls power to the
dishwasher.
Connects power to
tank and booster
heat circuits, pump
contactors, and drive
con tacto r.
Signals control power
connected to unit if
ON/OFF selector ON.
Starts pumps and
conveyor motors.
Stops pumps and
conveyor motors.
Refer to Figure 3.1 and Table 3.1 below for the location and function
of the operator controls and indicators on the remote control cabinet.
Red pilot
light
Figure 3.1
Operator Controls
Remote Control Cabinet
(Front Exterior View)
Indicates final rinse
temperature has
fallen below 180°F.
Dishwasher stops.
Table 3.1
Controls and Indicators
Remote Control Cabinet
CONTROL
~~
0
ON/OFF Switch
@Power ON light
@
Start switch
@
Stop switch
@Booster low
temperature lighl
20

Advertisement

Table of Contents
loading