10.TROUBLESHOOTING
When the engine will not start:
NO
Is there fuel in the tank?
YES
NO
Is the engine switch on?
YES
NO
Is there enough oil in the engine?
YES
NO
Is there a spark from
Replace the
the spark plug?
spark plug.
WARNING
Be sure there is no spilled
fuel around the spark pulg.
Spilled fuel may ignite.
If the engine still does not
start, take the generator to
an authorized dealer.
Refill the fuel tank.
Turn the engine switch on.
Add the recommended oil.
Still no
Take the generator to an
spark
authorized dealer.
To check:
1)Remove the spark plug cap and clean
any dirt from around the spark plug.
2)Remove the spark plug and install the
spark plug in the plug cap.
3)Set the plug side electrode on the cylin-
der head to ground.
4)Pull the recoil starter, sparks should
jump across the gap.
32

1. SAFETY INSTRUCTIONS

Our generators are designed to give safe and depend-
WARNING
able service if operated according to instructions.
Read and understand the Owner's Manual before op-
erating the generator. Failure to do so could result in
personal injury or equipment damage.
Exhaust gas contains poisonous carbon monoxide.
WARNING
Never run the generator in an enclosed area.
Be sure to provide adequate ventilation.
When installed in ventilated protection are to be
observed.
The muffler becomes very hot during operation and
WARNING
remains hot for a while after stopping the engine.
Be careful not to touch the muffler while it is hot.
Let the engine cool before storing the generator
indoors.
The engine exhaust system will be heated during op-
eration and remain hot immediately after stopping the
engine.
To prevent scalding, pay attention to the warning
marks attached to the generator.